Validated BP Monitors for For Specialist Use


ManufacturerModelTypePriceProtocolValidation StudyFeaturesNotesReference
A C Cossor & SonGreenlight 300ClinicOver £100International ProtocolIndependent4 x AA batteriesManual DeviceGraves JW, Tibor M, Blaithnead M, Klein L & Sheps SG. The Accoson Greenlight 300, the first non-automated mercury-free blood pressure measurement device to pass the International Protocol for blood pressure measuring devices in adults. Blood Pressure Monitoring 2004, 9(1):13-17
A&DTM-2430ABPMOver £100BHS A/AIndependentSoftware included. Data output facility to PC or printer. 3 x AA NiMH rechargeable (included) or AA AlkalinePalatini P, Frigo G, Bertolo O et al. Validation of the A&D TM-2430 device for ambulatory blood pressure monitoring and evaluation of performance according to sujects’ characteristics. Blood Pressure Monitoring 1998: 3:255-260
A&DTM2440 (Derivative of TM2441)ABPMOver £100ISO 81060-2:2013IndependentABPM deviceKazuomi Kario, Satoshi Hoshide, Kimiyo Saito, Keiko Sato, Haruna Hamasaki, Hiromi Suwa and Naoko Tomitani
Validation of the TM-2441 ambulatory blood pressure measurement device according to the ISO 81060-2:2013 standard
Blood Pressure Monitoring 2019, 24:38–41
A&DTM2441 ABPMOver £100ISO 81060-2:2013IndependentABPM deviceKazuomi Kario, Satoshi Hoshide, Kimiyo Saito, Keiko Sato, Haruna Hamasaki, Hiromi Suwa and Naoko Tomitani
Validation of the TM-2441 ambulatory blood pressure measurement device according to the ISO 81060-2:2013 standard
Blood Pressure Monitoring 2019, 24:38–41
A&DTM-2655Waiting Room Over £100BHS A/AIndependentMains PoweredValidated for self-assessment in pharmacies etcKobalava ZD, Ktoovskaya YV, Babaeva LA & Moiseev VS. Validation of TM-2655 oscillometric device for blood pressure measurement. Blood Pressure Monitoring 2006, 11 (2):87-90
A&DTM-2656Waiting Room Unknown PriceBHS A/AIndependentStatic, automatic arm cuffing system suitable for use in clinical settings for patients to self-measure BP.Wei-Fang Z, Ming L, Yuan-Yuan K, Yan L and Ji-Guang W.  Validation of the fully automated A&D TM-2656 blood pressure monitor according to the British Hypertension Society Protocol.  Blood Pressure Monitoring 2013, 18:223-226
Andon Health Co. Ltd.KD-391ClinicUnknown PriceInternational ProtocolIndependentWan y, Pan F, Liu Y, Liang Y, Yang Y, Zhao H & Xu Y. Validation of the Andon KD-391 semi-automated blood pressure monitor in adults according to the International Protocol. Blood Pressure Monitoring 2009, 14:181-184
Andon Health Co. Ltd.KD - 551 (Derivative of KD5917)Upper ArmUnknown Priceinternational protocol 2010IndependentWan-Gang Guo, Bing-Ling Li, Yong He, Yu-Sheng Xue, Hai-Yan Wang, Qiang-Sun Zheng and Ding-Cheng Xiang
Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement,
according to the European Society of Hypertension
International Protocol revision 2010
Blood Pressure Monitoring, 2014, 19:242–245
Andon Health Co. Ltd.KD - 5810 (Derivative of
KD- 5917)
Upper ArmUnknown Priceinternational protocol 2010IndependentWan-Gang Guo, Bing-Ling Li, Yong He, Yu-Sheng Xue, Hai-Yan Wang, Qiang-Sun Zheng and Ding-Cheng Xiang
Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement,
according to the European Society of Hypertension
International Protocol revision 2010
Blood Pressure Monitoring, 2014, 19:242–245
Andon Health Co. Ltd.KD - 5811 (Derivative of
KD- 5917)
Upper ArmUnknown Priceinternational protocol 2010IndependentWan-Gang Guo, Bing-Ling Li, Yong He, Yu-Sheng Xue, Hai-Yan Wang, Qiang-Sun Zheng and Ding-Cheng Xiang
Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement,
according to the European Society of Hypertension
International Protocol revision 2010
Blood Pressure Monitoring, 2014, 19:242–245
ArtsanaCS 410ClinicUnknown PriceInternational ProtocolIndependentPini C, Natalizi A, Gerosa PF, Frigerio M, Omboni S & Parati G. Validation of the Artsana CS 410 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension. Blood Pressure Monitoring 2008, 13:177-182
ArtsanaCS 610ClinicUnknown Priceinternational ProtocolIndependentPini C, Pastori M, Bacceschi J, Omboni S & Parati G. Validation of the Artsana CS610 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension. Blood Pressure Monitoring 2007, 12:179-184
BTLBTL-08 ABPM II (OEM derivative of Meditech ABPM-05)ABPMUnknown PriceBHS B/BIndependentBarna I, Keazei A & Dunai A. Evaluation of Meditech ABPM-04 ambulatory blood pressure measuring device according to the British Hypertension Society protocol. Blood Pressure Monitoring 1998, 3:363-368
DinamapProcare 100ClinicOver £100International ProtocolIndependent6VDC rechargeable batteryReinders A, Reggiori F & Shennan A. Validation of the Dinamap ProCare blood pressure device according to the International Protocol in an adult population. Blood Pressure Monitoring 2006, (11) 5: 293-296
DinamapProcare 200 (Derivative of Dinamap 100)ClinicOver £100International ProtocolIndependentReads BP & temp. 6VDC rechargeable batterReinders A, Reggiori F & Shennan A. Validation of the Dinamap ProCare blood pressure device according to the International Protocol in an adult population. Blood Pressure Monitoring 2006, (11) 5: 293-296
DinamapProcare 230 (Derivative of Procare 100)ClinicOver £100International ProtocolIndependentReinders A, Reggiori F & Shennan A. Validation of the Dinamap ProCare blood pressure device according to the International Protocol in an adult population. Blood Pressure Monitoring 2006, (11) 5: 293-296
DinamapProcare 420 (Derivative of Procare 100)ClinicOver £100International ProtocolIndependentReinders A, Reggiori F & Shennan A. Validation of the Dinamap ProCare blood pressure device according to the International Protocol in an adult population. Blood Pressure Monitoring 2006, (11) 5: 293-296
EDANSA - 10ClinicUnknown Priceinternational ProtocolIndependentPlease note that this machine only passed the static part of ISO, not for ABPMValidation of the EDAN SA-10 ambulatory blood pressure monitor in general population according to the Association for the
Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for
Standardization Universal Standard
Bing Wang, Kui Liu, Linyi Li, Shimin Yin, and Jie Ren
Blood Pressure Monitoring: August 2022 - Volume 27 - Issue 4 - p 276-279
doi: 10.1097/MBP.0000000000000600
EnvitecC-WismarPhysioQuantABPMUnknown PriceInternational ProtocolIndependentMinor protocol violation; only 2 observers used in the validation studyLangewitz W & Tanner S. Validation of the PhysioQuant blood pressure measuring monitor in adults. Blood Pressure Monitoring 2009, 14(5): 220-221
ErgolineErgoscan (Derivative of EnvitecWismar PhysioQuant)ABPMUnknown PriceInternational ProtocolIndependentMinor protocol violation; only 2 observers used in the validation studyLangewitz W & Tanner S. Validation of the PhysioQuant blood pressure measuring monitor in adults. Blood Pressure Monitoring 2009, 14(5): 220-221
ERKA Kallmeyer MedizintechnikErkameter 125 PROClinicUnknown Priceinternational protocol 2010IndependentB Beime, C Deutsch, R Kruger, E Zimmermann and P Bramlage.  Validation of the blood pressure measurement device Erkameter 125 PRO according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2016, 21:356-360
ET Medical DevicesCardioline Walk200B (OEM derivative of IEM Mobil-O-Graph)ABPMUnknown PriceBHS A/A, International ProtocolIndependentFranssen PML & Imholz BPM. Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria. Blood Pressure Monitoring 2010, 15: 229-231. Weiss W, Tolle M, Zidek W & van der Giet M. Validation of the Mobil-O-Graph: 24h-blood pressure measurement device. Blood Pressure Monitoring, 15:225-228
GECarescape V100 (Derivative of Procare 100)ClinicOver £100International ProtocolIndependent6VDC rechargeable batteryReinders A, Reggiori F & Shennan A. Validation of the Dinamap ProCare blood pressure device according to the International Protocol in an adult population. Blood Pressure Monitoring 2006, (11) 5: 293-296
GE HealthcareTonoport VABPMUnknown PriceInternational ProtocolIndependent2 x AA batteriesHaensel A, Utech K & Langewitz W. Validation of Tonoport V blood pressure measuring monitor in adults. Journal of Human Hypertension 2005, 0:1-6
HealthworksSCLV-2007 Cardio-Vascular Lab (Derivative of Spengler KP-7500D)ClinicOver £100International ProtocolIndependentUSB drivenABI, stroke volume & cardiac outputBarna I, Keazei A & Dunai A. Evaluation of Meditech ABPM-04 ambulatory blood pressure measuring device according to the British Hypertension Society protocol. Blood Pressure Monitoring 1998, 3:363-368
HeathSTATS InternationalBproABPMOver £100International ProtocolIndependent3C CR 2032 3V coin batteryWrist deviceNair D, Tan S-Y, Gan H-W, Lim S-F, Tan J, Zhu M, Gao H, Chua N-H, Peh W-I & Mak K-H. Research letter: The use of ambulatory tonometric radial arterial wave capture to measure ambulatory blood pressure: the validation of a novel wrist-bound device in adults. Journal of human Hypertension 2008, 22:220-222
Heine GammaG7 (G5)AneroidUnknown PriceInternational ProtocolIndependentDorigatti F, Bonso E, Zanier A & Palatini P. Validation of Heine Gamma G7 (G5) and XXL-LFR aneroid devices for blood pressure measurement. Blood Pressure Monitoring 2007, 12:29-33
Heine GammaXXL-LFAneroidUnknown PriceInternational ProtocolIndependentDorigatti F, Bonso E, Zanier A & Palatini P. Validation of Heine Gamma G7 (G5) and XXL-LFR aneroid devices for blood pressure measurement. Blood Pressure Monitoring 2007, 12:29-33
Hingmed WBP-02AABPMUnknown Priceinternational protocol 2010IndependentValidation of the Hingmed WBP-02A device for ambulatoryblood pressure monitoring according to the European Society of
Hypertension International Protocol revision 2010. Claudio Fania, Leonardo Vezzù, Ilaria Lazzaretto and Paolo Palatini.
Blood Pressure Monitoring 2019, 24:151–154
HoMedicsWGNBPA-540ClinicUnknown PriceBHS A/AIndependentYarrows S. Accuracy of the HoMedics Walgreens Deluxe Arm Blood pressure device (WGNBPA-540) compared with auscultatiion in 85 individuals. Blood Pressure Monitoring 2001, 16:200-202
IEMMobil-O-Graph NG 24/48h ABPMABPMOver £100BHS A/A, International ProtocolIndependentSoftware included. 2 x AA rechargeable charger includedFranssen PML & Imholz BPM. Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria. Blood Pressure Monitoring 2010, 15: 229-231. Weiss W, Tolle M, Zidek W & van der Giet M. Validation of the Mobil-O-Graph: 24h-blood pressure measurement device. Blood Pressure Monitoring, 15:225-228
InBodyBPBIO250ClinicUnknown PriceInternational ProtocolIndependentKollias A, Gravvani A, Anagnostopoulos I, Kyriakoulis K, Bountzona I, Menti A and Stergiou G. Validation of the InBody
BPBIO250 oscillometric blood pressure monitor for professional office use in general population according to the Associatio
for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for
Standardization Universal Standard. Blood Pressure Monitoring 2020, 25:115–117
InBodyBPBIO320Waiting Room Unknown PriceInternational ProtocolIndependentKiosk device for public useKollias A, Stamolliu E, Kyriakoulis KG, Papadatos SS, Stergiou, GS. Validation of the single-cuff oscillometric blood pressure
monitor InBody BPBIO320 for public use according to the 2010 European Society of Hypertension International Protocol.
Blood Pressure Monitoring 2019, 24:30-32
InBodyBPBIO750 (Derivative of
BPBIO320)
Waiting Room Unknown Priceinternational protocol 2010IndependentKiosk device for public useKollias A, Stamolliu E, Kyriakoulis KG, Papadatos SS, Stergiou, GS. Validation of the single-cuff oscillometric blood pressure
monitor InBody BPBIO320 for public use according to the 2010 European Society of Hypertension International Protocol.
Blood Pressure Monitoring 2019, 24:30-32
KeelerBig Ben Square, Round , Windsor, Palm, Classic (All derivative of Riester Big Ben Square)AneroidUnknown PriceInternational ProtocolBHSTested and approved by the BIHS Validation Service
MedavalQMon-20ClinicUnknown PriceANSI/ESH/ISO 81060–2:2018IndependentSergio Rico-Martín, Marisol Sánchez-Bacaicoa, Julián F. Calderón-García, Pedro J. Labrador-Gómez, Jorge M. De Nicolás
Jiménez, Juan Villa-Rincón, Nicolás R. Robles, Carlos Guijarro, Chiara Iammarino, Enrique Rodilla-Salas and Juan F. Sánchez
Muñoz-Torrero
Validation of the QMon-20 oscillometric blood pressure monitor for professional office use in the general population
according to the ANSI/ESH/ISO 81060–2:2018 protocol
Blood Pressure Monitoring 2021, 26:393–395
MeditechABPM-04ABPMOver £100BHS B/BIndependent4 x AA Alkaline or rechargeableBarna I, Keazei A & Dunai A. Evaluation of Meditech ABPM-04 ambulatory blood pressure measuring device according to the British Hypertension Society protocol. Blood Pressure Monitoring 1998, 3:363-368
MeditechABPM-05 (Derivative of ABPM-04)ABPMOver £100BHS B/BIndependentBarna I, Keazei A & Dunai A. Evaluation of Meditech ABPM-04 ambulatory blood pressure measuring device according to the British Hypertension Society protocol. Blood Pressure Monitoring 1998, 3:363-368
MeditechABPM-06ABPMOver £100BHS A/AIndependentValidated and approved against the BHS protocol only. Protocol violations noted for ESH-IP2 and IOSHermányi Z, Pokoly B, Visolyi G, Barna I. Evaluation of Meditech ABPM-06 ambulatory blood pressure measuring device,
according to the European Society of Hypertension, the British Hypertension Society and the International Organization for
Standardization protocol. Blood Press Monit. 2019; 24:208–211
Medset MedizintechnikScanlight III (OEM derivative of IEM Mobil-O-Graph)ABPMUnknown PriceBHS A/A, International ProtocolIndependentFranssen PML & Imholz BPM. Evaluation of the Mobil-O-Graph new generation ABPM device using the ESH criteria. Blood Pressure Monitoring 2010, 15: 229-231. Weiss W, Tolle M, Zidek W & van der Giet M. Validation of the Mobil-O-Graph: 24h-blood pressure measurement device. Blood Pressure Monitoring, 15:225-228
MicrolifeWatchBP HomePregnancy Under £100BHS A/AIndependentL-XL cuff available. 4 x AA batteries mains adaptor availableAF detection in this device does not mean that this device is validated for use in patients with AFChung Y, de Greeff A & Shennan A. Valdiation and compliance of a home monitoring device in pregnancy: Microlife Watch BP Home. Hypertension in Pregnancy, 28, 3:348-359.
MicrolifeWatchBP 03ABPMOver £100International ProtocolIndependentPC link. 4 x AAA Alkaline BatteriesAF detection in this device does not mean that this device is validated for use in patients with AFRagazzo F, Saladini F & Palatini P. Validation of the Microlife WatchBP 03 device for clinic, home and ambulatory blood pressure measurement, according to the International Protocol. Blood Pressure Monitoring 2010, 15(1):59-62
MicrolifeA3PCClinicUnknown PriceANSI/AAMI/ISO 81060-2:2013Independentapproved for use in diabetes, but with medium large cuff onlyValidation of the Microlife BP A3 PC upper arm blood pressure monitor in patients with diabetes mellitus according to the
ANSI/AAMI/ISO 81060-2:2013 protocol
Beate Beimea; Ralf Krügera; Gertrud Hammelb; Peter Bramlagea; Cornelia Deutscha
Blood Press Monitoring: February 2018; 23(1):52-57. doi: 10.1097/MBP.0000000000000302
MicrolifeB3AFIBUpper ArmUnknown PriceANSI/AAMI/ISO 81060-2:2013IndependentBeime, Beate; Bramlage, Carsten; Krüger, Ralf; Deutsch, Cornelia; van Mark, Gesine; Bramlage, Peter; Botta, Beate
Validation of the Microlife BP B3 AFIB upper arm blood pressure monitor in adults and adolescents according to the
ANSI/AAMI/ISO 81060-2:2019 protocol
Blood Pressure Monitoring: August 2021 - Volume 26 - Issue 4 - p 299-304
doi: 10.1097/MBP.0000000000000530
MicrolifeWatchBP OfficeClinicUnknown PriceInternational ProtocolIndependentBluetooth, 3 function modes allowing simultaneous measurement in both arms.Stergiou GS, Tzamournanis D, Protogerou A, Nasothimiou E & Kapralos C. Validation of the Microlife WatchBP Office professional device for office blood pressure measurement according to the International Protocol. Blood Pressure Monitoring 2008, 13:299-303.
MicrolifeWatchBP Office ABIClinicUnknown PriceInternational ProtocolIndependentValidated for upper arm use only. NB AF detection does not mean that this device has been validated for use in patients with AFSaladini F, Benetti E, Masiero S & Palatini P. Accuracy of Microlife WatchBP Office ABI monitor assessed according to the 200
European Society of Hypertension protocol and the British Hypertension Society protocol. Blood Pressure Monitoring 2011,
16:258-261
MicrolifeWatchBP Office ABIObese AdultsUnknown PriceBHS A/AIndependentValidated for upper arm use only. NB AF detection does not mean that this device has been validated for use in patients with AFMasiero S, Saladini F, Benetti E & Palatini P. Accuracy of the Microlife large-extra large sized cuff (32-52cm) coupled to an automatic oscillometric device. Blood Pressure Monitoring 2011, 16:99-102
Microlife3AS1-2PregnancyUnknown PriceBHS B/A, BHS A/A, International ProtocolIndependentSemi-automatic. 2 x AAA batteriesValidated for use in pregnancy only. An insufficient population of pre-eclamptic patients was used in the validation study to inform recommendation. Minor protocol violation; only 2 observers used in the validation study. Validated in pregnant population with low blood pressure in a low resource settings in low and middle income countriesde Greef A, Nathan , Stafford N, Liu B & Shennan A. Development of an acccurate oscillometric blood pressure device for low resource settings. Blood Pressure Monitoring 2008, 13:342-348. Nathan HL, de Greeff A, Hezelgrave NL, Chappell LC and Shennan AH. An accurate semiautomated oscillometric blood pressure device for use in pregnancy (including pre-eclampsia) in a low-income and middle-income country populaton: the Microlife 3AS1-2. Blood Pressure Monitoring 2015, 20:52-55. Nathan, L, de Greeff A, Hezelgrave NL, Chappell LC and Shennan A. Accuracy of the Microlife 3AS1-2 blood pressure device in a pregnant population with low blood pressure. Blood Pressure Monitoring 1025, 20:299-302
MindrayAccutor V (Derivative of Mindray Accutor Plus)ClinicOver £100BHS A/AIndependentChild, Standard Adult & Large Adult Cuffs: 12v rechargeable SLA or 10.8v rechargeable lithiam iron batteryAnwar YA, Tendler BE, McCabe EJ et al. Evaluation of the Datascope Accutorr Plus according to the Association for Advancement of Mdical Instrumentation. Blood Pressure Monitoring. 1997, 2:105-110
MindrayAccutor V (Derivative of Mindray Accutor Plus)ChildrenOver £100International ProtocolIndependentChild, Standard Adult & Large Adult Cuffs: 12v rechargeable SLA or 10.8v rechargeable lithiam iron batteryTested in normotensive children only. No evidence of accuracy in hypertensive children.Wong SN, Sung RYT & Leung LCK. Validation of three oscillometric blood pressure devices against auscultatory Mercury sphygmomanometers in children. Blood Pressure Monitoring 2006, 11:281-291
MindrayAccutor PlusClinicOver £100BHS A/AIndependentChild, Standard Adult & Large Adult Cuffs: 12v rechargeable SLA or 10.8v rechargeable lithiam iron batteryAnwar YA, Tendler BE, McCabe EJ et al. Evaluation of the Datascope Accutorr Plus according to the Association for Advancement of Mdical Instrumentation. Blood Pressure Monitoring. 1997, 2:105-110
MindrayAccutor PlusChildrenOver £100International ProtocolIndependentChild, Standard Adult & Large Adult Cuffs: 12v rechargeable SLA or 10.8v rechargeable lithiam iron batteryTested in normotensive children only. No evidence of accuracy in hypertensive children.Wong SN, Sung RYT & Leung LCK. Validation of three oscillometric blood pressure devices against auscultatory Mercury sphygmomanometers in children. Blood Pressure Monitoring 2006, 11:281-291
MindrayBeneView T5Vital Signs MonitorUnknown PriceInternational ProtocolBIHSValidated for BP measurement onlyTested and approved by the BHS Validation Service
MindrayBeneVision N12 (Derivative
of BeneView T5)
Vital Signs MonitorUknown PriceInternational ProtocolBIHSValidated for BP measurement onlyTested and approved by the BHS Validation Service
MindrayiMEC12 (Derivative of Mindray BeneView T5)Vital Signs MonitorUnknown PriceInternational ProtocolBIHSValidated for BP measurement onlyTested and approved by the BHS Validation Service
MindrayiPM 12 (Derivative of Mindray BeneView T5)vital Signs MonitorUnknown PriceInternational ProtocolBIHSValidated for BP measurement onlyTested and approved by the BHS Validation Service
Mortara (formerly Tibia Medical)Ambulo 2400ABPMOver £100BHS A/AIndependent2 x AA Alkaline or NiMH batteriesAlpert BS. Validation of the Tiba Medical Ambulo 2400 ambulatory blood pressure monitor to the ISO and British protocol. Blood Pressure Monitoring 2010, 15:275-277
NisseiDM-3000ClinicOver £100International ProtocolIndependentAuscultatory & Oscillometric function. Rechargeable battery pack. AC mains adaptor includedValidated for use in automatic oscillometric mode and in blinded auscultatory mode at default deflation rate of 2.5mmHg/secTasker F, de Greef A & Shennan A. Development and validation of a blinded hyprid device according to the European Hypertension Society Protocol: Nissei DM-3000. Journal of Human Hypertension (2010), doi: 10.1038/jhh.2009.113
Novacor Diasys 3ABPMOver £100AAMI/ANSI/ISO 81060-2:2013IndependentAtkins N, Fania C and Palatini P. Validation of the blood pressure measurement technolog used in the Novacor Diasys 3 (DIS
0001-00) upper arm device for ambulatory blood pressure measurement, according to the requirements of the
AAMI/ANSI/ISO 81060-2:2013 standard (for both a general study and a cardiac-stress study in adults) and of the European
Society of Hypertension International Protocol revision 2010.
Blood Pressure Monitoring 2021, 26:70–77
Novacor Diasys 3 PlusABPMOver £100international protocol 2010IndependentABPM deviceApproved according to the International Protocol (2010)Atkins N, Fania C and Palatini P. Validation of the blood pressure measurement technology used in the Novacor Diasys 3 Plu
(DIP-0001-00) upperarm device for ambulatory blood pressure measurement, according to AAMI/ANSI/ISO 81060-2:2013,
ESH-IP 2010 and MEDDEV 2.7/1. Blood Pressure Monitoring 2020, 25:359–367
OmronM7 (HEM-780-E)Obese AdultsOver £100International ProtocolIndependentOne-size cuff 22-42cm, 4 x AA batteries, AC mains adapter availableAlso validated for use in pregnancy - See separate noteEl Feghali RN, Topouchian JA, Pannier BM, El Assaad HA & Asmar RG. Validation of the Omron M7 (HEM0780-E) blood pressure measuring devbice in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension. Blood Pressure Monitoring 2007, 12: 173-178.
OmronM7 (HEM-780-E)Pregnancy & Pre-eclampsiaOver £100International ProtocolIndependentOne-size cuff 22-42cm, 4 x AA batteries, AC mains adapter availableAlso validated for use in obese adults - See separate notede Greef A, Beg Z, Gangji Z, Dorney E & Shennan A. Accuracy of inflationary versus deflationary oscillometry in pregnancy and pre-eclampsia; Omron MIT versus Omron M7 Blood Pressure Monitoring 2009, 14:37-40
PAR MedizintechnikPhysio Port (Derivative of Tonoport VI)ABPMUnknown PriceInternational Protocol 2010IndependentAbou-Dakn M, Dohmen C and Wenzel S.  Validation of the Tonoport VI ambulatory blood pressure monitor in adults according to the European Society of Hypertension International Protocol revision 2010. Journal of Human Hypertension (2016), 1-4
PAR MedizintechnikTonoport VIABPMUnknown PriceInternational Protocol 2010IndependentAbou-Dakn M, Dohmen C and Wenzel S.  Validation of the Tonoport VI ambulatory blood pressure monitor in adults according to the European Society of Hypertension International Protocol revision 2010. Journal of Human Hypertension (2016), 1-4
ReisterRBP-100 (Derivative of
Microlife WatchBP Office
ABI)
ClinicUnknown PriceInternational ProtocolIndependentValidated for upper arm use only. NB AF detection does not mean that this device has been validated for use in patients wit
AF
Saladini F, Benetti E, Masiero S & Palatini P. Accuracy of Microlife WatchBP Office ABI monitor assessed according to the 200
European Society of Hypertension protocol and the British Hypertension Society protocol. Blood Pressure Monitoring 2011,
16:258-261
RiesterBig Ben SquareAneroidUnknown PriceInternational ProtocolBIHSTested and approved by the BHS Validation Service
RiesterBig Ben Round (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBIHSTested and approved by the BHS Validation Service
RiesterE-mega (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBIHSTested and approved by the BHS Validation Service
Riesterexacta (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBIHSTested and approved by the BHS Validation Service
RiesterMinimus II (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBIHSTested and approved by the BHS Validation Service
RiesterMinimus III (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBIHSTested and approved by the BHS Validation Service
RiesterPrecisa N Shock-proof (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBIHSTested and approved by the BHS Validation Service
Riesterprecisa N (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBIHSTested and approved by the BHS Validation Service
RiesterR1 shock-proof (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBHSTested and approved by the BHS Validation Service
Riesterri-cardio (Derivative of SunTech Medical Oscar 2)ABPMUnknown PriceBHS A/A, International ProtocolIndependentGoodwin J, Bilous M, Winship S, Finn P & Jones SC. Validation of the Oscar 2 oscillometric 24-h ambulatory blood pressure
monitor according to the British Hypertension Society protocol. Blood pressure Monitoring 2007, 12:113-117.
Jones SC, Bilous M, Winship S, Finn P & Goodwin J. Validation of the Oscar 2 oscillometric 24-hour ambulatory blood pressur
monitor according to the International Protocol for the validation of blood pressure measuring devices. Blood Pressure
Monitoring 2004,9(4) :219-223
Riesterri-medic (Derivative of SunTech 247)Vital Signs MonitorUnknown PriceBHS A/A, International ProtocolIndependentFriz HP, Facchetti R Primitz L, Beltrame L, Glbiati V, Bicioppo A, Bombelli M & Sega R.  Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypetension Society protocol, the International Protocol and the Association of Medical Instrumentation standards.  Blood Pressure Monitoring 2009, 14:222-227
Riesterri-san (Derivative of Big Ben Square)AneroidUnknown PriceInternational ProtocolBHSTested and approved by the BHS Validation Service
SchillerBR-102 PlusABPMOver £100International ProtocolIndependent2 x rechageable AA batteriesDenchev SV, Simova II & Matveev MG. Evaluation of the Schiller BR-102 Plus non-invasive ambulatory blood pressure monitor according to the International Protocol introduced by the Working Group on Blood Pressure Monitoring of the European Society of Hypertension. Blood Pressure Monitoring 2007, 12:329-333
SOMNOmedics SOMNOmedics ABPMproUpper ArmUnknown PriceInternational ProtocolIndependentValidated up to an upper arm circumference of 39 cmRoth B, Bothe TL, Patzak A, Pilz N. Validation of the ABPMpro ambulatory blood pressure monitor in the general population
according to AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018). Blood Press Monit. 2023 Jun 1;28(3):158-162. doi:
10.1097/MBP.0000000000000640. Epub 2023 Apr 5. PMID: 37016982; PMCID: PMC10132455.
SorinAgilisABPMOver £100International ProtocolIndependentSoftware included. 2 x AA Alkaline or NiMH rechargeableMallion JJM, Pierre H, Neuder Y, Ormezzano O & Baguet JP. Validation of the Agilis ambulatory blood pressure monitor according to the European Society of Hypertension Intewrnational Protocol for validation of blood pressure measuring devices in adults. Blood Pressure Monitoring 2005, 10(2):97-101
SpacelabsSL90207ABPMOver £100BHS B/BIndependentSoftware and download cable included. 4 x AA batteriesO’Brien E, Mee F, Atkins N & O’Malley K. Accuracy of the SpaceLabs 90207 determined by the British Hypertension Society Protocol. J Hypertens 1991, 9 (suppl 5): S25-S31
SpacelabsSL 90217ABPMOver £100BHS A/AIndependentSofware & download cable included. Ultralight. 3 x AA batteriesBaumgart P & Kamp J. Accuracy of the SpaceLabs Medical 90217 ambulatory blood pressure monitor. Blood Pressure Monitoring 1998, 3:303-307
Spacelabs90227 OnTrakABPMUnknown PriceBHS A/AIndependentApproved in adults only via BHS Protocol.
Not Approved: ESH IP2 Protocol violation re BP distribution. AAMI Protocol violation re subject inclusion.
de Greef A and Shennan A. Validation of the Spacelabs 90227 OnTrak device according to the European and British
Hypertension Societies as well as the American protocols. Blood Pressure Monitoring. 2020, 25:110–114
SpenglerPro MUpper ArmUnknown PriceInternational ProtocolIndependentde Greef A, Ahmed N, Sheppard E & Shennan A. A self-measurement device suitable for hospital use: validation of the
Spengler Pro M according to the International Protocol of the European society of Hypertension. Blood Pressure Monitoring
2008, 13:183-186
SuntechOscar 2ABPMUknown PriceBHS A/A, International ProtocolIndependent2 x AA Alkaline or NiMH rechargeableGoodwin J, Bilous M, Winship S, Fin P & Jones SC, Calidtion of the Oscar 2 oscillometric 24-h ambulatory blood pressure monitor according to the British Hypertension Society Protocol. Blood Pressure Monitoring, 2007, 12:113-117. Jones SC, Bilou M, WinshipS, Finn P & Goodwin J. Validation of the OSCAR 2 oscillometric 24-hour ambulatory blood pressure monitor according to the International Protocol for the validation of blood pressure monitoring devices in adults. Blood Pressure Monitoring 2004, 9(4):219-225.
UnimedicTensiodayABPMOver £100BHS A/AIndependent4 x AA batteries
UscomBP+ (Derivative of
Tonoport VI)
ClinicOver £100international protocol 2010IndependentAC power supply & 3 cuffs included (Small Adult, Adult & Large Adult Cuffs), Graphic display with waveformsIn the absence of a recognised protocol for testing central pressure accuracy, this device is validated for brachial
measurement only
Abou-Dakn M, Dohmen C and Wenzel S. Validation of the Tonoport VI ambulatory blood pressure monitor in adults
according to the European Society of Hypertension International Protocol revision 2010. Journal of Human Hypertension
(2016), 1-4
Welch AllynABPM 6100 (Derivative of Suntech Oscar 2)ABPMOver £100BHS A/AIndependent2 x AA batteriesGoodwin J, Bilous M, Winship S, Fin P & Jones SC. Validation of the Oscar 2 oscillometric 24-h ambulatory blood pressure monitor according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:113-117
Welch AllynABPM-7100 (Derivative of Mobil-O-Graph NG 24/48H ABPM)ABPMUnknown PriceBHS A/AIndependentValidation of the Mobil-O-Graph 24 h-blood pressure measurement device.  Weiss W, Tolle M, Zidek W & van der Giet M. Blood Pressure Monitoring 2010, 15:225-228
Welch AllynProBP 2400 (Derivative of Microlife WatchBP Office ABI)ClinicUnknown PriceBHS A/A, International ProtocolIndependentValidated for upper arm use onlySaladini F, Benetti E, Masiero S and Palatini P.  Accuracy of Microlife WatchBP Office ABI monitor assessed according to the 2002 European Society of Hypertension protocol and the British Hypertension Society protocol.  Blood Pressure Monitoring 2011, 16:258-261
Welch AllynProBP 2400 (Derivative of Microlife WatchBP Office ABI)Obese AdultsUnknown PriceBHS A/AIndependentValidated for upper arm use onlyMasiero S, Saladini F, Benetti E, and Palatini P.  Accuracy of the Microlife large-extra large-sized cuff (32-52cm) coupled to an automatic oscillometric device.  Blood Pressure Monitoring 2011, 16:99-102
Welch AllynProBP 3400Upper ArmUnknown PriceBHS A/AIndependentMains PoweredAlpert B. Validation of the Welch Allyn ProBP 3400: a device for modern medical practice. Blood Pressure Monitoring 2011,
16:156-158
WithingsBPM Connect (WPM05)Pregnancy & Pre-eclampsiaOver £100International ProtocolIndependentZelveian P, Topouchian J, Hakobyan Z, Asmar J, Gharibyan H, Asmar R
Clinical Accuracy of the Withings BPM Connect for Self-Blood Pressure Measurements in Pregnancy and Pre-Eclampsia:
Validation According to the Association for the Advancement of Medical Instrumentation/European Society of
Hypertension/International
Organization for Standardization Universal Standard
Vascular Health and Risk Management, 2022, 18, 181–189
WithingsBPM Connect Pro
(Derivative of BPM
Connect WPM05)
ClinicUnknown PriceInternational ProtocolIndependentZelveian P, Topouchian J, Hakobyan Z, Asmar J, Gharibyan H, Asmar R
Clinical Accuracy of the Withings BPM Connect for Self-Blood Pressure Measurements in Pregnancy and Pre-Eclampsia:
Validation According to the Association for the Advancement of Medical Instrumentation/European Society of
Hypertension/International
Organization for Standardization Universal Standard
Vascular Health and Risk Management, 2022, 18, 181–189
YuWellYE900ClinicUnknown PriceInternational ProtocolIndependentAlso validated for paediatric use in a clinical settingHui-Jie Zhang, Juan Zhang, Su-Lan Wang, Jin Zhang, Li-Ni Teng, Shu-Juan Zhang, De-Jun Zhou and Ming-Zhi Long.
Validation of the YuWell YE900 oscillometric blood pressure monitor for professional office use in adults and children
according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018)
Blood Pressure Monitoring 2021, 26:396–399