Validated BP Monitors for Home Use


ManufacturerModelTypeProtocolValidation StudyFeaturesNotesReference
A&DUA-1010 (Derivative of UA-1020)Upper ArmBHS A/AIndependent50 reading memoryWei-Fan Z, Yuan-Yuan K, Ming L, Yan L and Ji-Guang W.  Validation of the A&D UA-1020 upper-arm blood pressure monitor for home blood pressure monitoring according to the British Hypertension Society Protocol.  Blood Pressure Monitoring 2013, 18:177-181
A&DUA-704Upper ArmBHS A/AIndependent30 reading memory, manual inflation. 1 x AA batteryMinor protocol violation; only 2 observers used in the validation studyKobolava ZD, Kotosvkya YV & Rodionov E. Validation of semi-automatic device UA704 for self-measurement of blood pressure. Blood Pressure Monitoring 2005, 10(4):223-225
A&DUA-705Upper ArmBHS A/AIndependent30 reading memory, manual inflation. 1 x AA batteryMinor protocol violation; only 2 observers used in the validation studyVerdecchia P, Angeli F, Gattobigio R, Angeli E Pede S & Pittavini L. Valdiation of the A&D UA-705 device for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension. Vascular Health & Risk Management 2007: 3(4):1-12
A&DUA-767BT (Derivative of UA-774 & UA-767 Plus)Upper ArmBHS A/AIndependentBluetooth output only available to telemedicine service providers. 4 x AA batteries mains adaptor availableMinor protocol violation: only 2 observers used in the validation studyVerdeccia P, Angeli F, Poeta F, Reboldi GP, Borgioni C, Pittavini L & Porcellati C. Validation of the A&D UA-774 (UA-767Plus) device for self-measurement of blood pressure. Blood Pressure Monitoring 2004, 9(4):225-229
A&DUA-767PC (Derivative of UA-774 & UA-767 Plus)Upper ArmBHS A/AIndependent126 reading memory, optional software for use with PC. 4 x AA batteriesMinor protocol violation: only 2 observers used in the validation studyVerdeccia P, Angeli F, Poeta F, Reboldi GP, Borgioni C, Pittavini L & Porcellati C. Validation of the A&D UA-774 (UA-767Plus) device for self-measurement of blood pressure. Blood Pressure Monitoring 2004, 9(4):225-229
A&DBP UB-543Upper ArmInternational Protocol 2010IndependentCorrect position guidance indicator. 2 batteriesFania C, Benetti E, Palatini P.  Validation of the A&D BP UB-543 wrist device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2015, 20:237-240
A&DUA-767S (Derivative of UA-651)Upper ArmInternational Protocol 2010IndependentBenetti E, Fania C and Palatini P. Validation of the A&D BP UA-651 device for home blood pressure measurement
according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure
Monitoring 2014, 19:50-53. Benetti E, Fania C and Palatini P. Validation of the A&D BP UA-651 device with a widerange cuff for home blood pressure measurement according to the European Society of Hypertension International
Protocol revision 2010. Blood Pressure Monitoring 2015, 20:164-167
A&DUA-767S-W (Derivative of UA651)Upper ArmInternational Protocol 2010IndependentBenetti E, Fania C and Palatini P. Validation of the A&D BP UA-651 device for home blood pressure measurement
according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure
Monitoring 2014, 19:50-53. Benetti E, Fania C and Palatini P. Validation of the A&D BP UA-651 device with a widerange cuff for home blood pressure measurement according to the European Society of Hypertension International
Protocol revision 2010. Blood Pressure Monitoring 2015, 20:164-167
A&DTM-2657P (Derivative of TMTM2656)Upper ArmBHS A/AIndependentWei-Fang Zeng, Ming Liu, Yuan-Yuan Kang, Yan Li, Ji-Guang Wang
Validation of the fully automated A&D TM-2656 blood pressure monitor according to the British Hypertension
Society Protocol
Blood Press Monitoring, 2013 Aug;18(4):223-6
A&DUM-201Upper ArmInternational ProtocolIndependent4 x AA Batteries or AC Adapter. Latex-free cuffs. Large cuff up to 45cmFania C, Albertini F & Palatini P. Validation of the A&D UM-201 device for office blood pressure measurement
according to the European Society of Hypertension International Protocol Revision 2010. Blood Pressure
Monitoring 2017, 22:234-237
A&DUM-211ClinicInternational ProtocolIndependent99 reading memory. 4 x AAA Batteries or AC Adapter.XL Cuff available but not tested in the validation studyFania C, Albertini F & Palatini P. Validation of the A&D UM-211 device for office blood pressure measurement
according to the European Society of Hypertension International Protocol Revision 2010. Blood Pressure
Monitoring 2017, 22:302-305
A&D BP UB-542WristInternational Protocol 2010IndependentAF detection in this device does not mean that it will accurately measure blood pressure in patients with AFSaldini F. Benetti E, Fania C and Palatini P.  Validation of the A&D BP UB-542 wrist device for home blood pressure measurement according to the European Soceity of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2013, 18:219-222
A&D UA-85X series comprising UA-851/2/3/4/5Upper ArmInternational ProtocolIndependentPrices vary between modelsBonso E, Ragazzo F & Palatini P. Validation of A&D UA-85X device for blood pressure measurement. Blood Pressure Monitoring 2008, 13:339-341
A&D UA-611 (Derivative of UA-651)Upper ArmInternational Protocol 2010Independent4 x AAA batteries50 reading memoryBennetti E, Fania C and Palatini P. Validation of the A&D BP UA-651 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.    Blood Pressure Monitoring 2014, 19:50-53
A&D UA-651Upper ArmInternational Protocol 2010Independent4 batteries, AC adapterAlso validated for use with a wide-range cuff: 22-42 cmBenetti E, Fania C and Palatini P. Validation of the A&D BP UA-651 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.    Blood Pressure Monitoring 2014, 19:50-53. Benetti E, Fania C and Palatini P. Validation of the A&D BP UA-651 device with a wide-range cuff for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 20:164-167
A&D UA-651 PlusUpper ArmInternational Protocol 2010Independent60 reading memory. 4 x AA batteriesStandard cu ts 22-32cmAlpert BS. Validation of the A&D UA-651 Plus/UA-651SL Plus automated sphygmomanometer according to the ISO
81060-2, 2018 and ISO 81060-2 Amendment 1, 2020, which resulted in the currently pending Amendment to Amendment 1.
J Clin Hypertens (Greenwich). 2022 Apr;24(4):513-518. doi: 10.1111/jch.14464. Epub 2022 Mar 21. PMID: 35312160;
PMCID: PMC8989751.
A&D UA-656BLE (Derivative of
UA-651Plus)
Upper ArmIndependentStandard Cuff sze 22-42cmAlpert BS. Validation of the A&D UA-651 Plus/UA-651SL Plus automated sphygmomanometer according to the ISO 81060-2,
2018 and ISO 81060-2 Amendment 1, 2020, which resulted in the currently pending Amendment to Amendment 1. J Clin
Hypertens (Greenwich). 2022 Apr;24(4):513-518. doi: 10.1111/jch.14464. Epub 2022 Mar 21. PMID: 35312160; PMCID:
PMC8989751.
A&D UA-767Upper ArmBHS A/AIndependent4 AA batteriesLower accuracy at upper pressure range. Minor protocol violation; only 2 observers used in the valdiation studyRogoza AN, Pavlova TS & Sergeeva MV. Validation of A&D UA-767 device for the self-measurement of blood pressure. Blood Pressure Monitoring 2000, 5:227-231
A&D UA-767 PlusUpper ArmBHS A/AIndependent30 reading memory. 4 x AA batteries mains adaptor availableMinor protocol variation; only 2 observers used in the validation studyVerdecchia P, Angeli F, Poeta F, Reboldi GP, Borgioni C, Pittavini L & Porcellati C. Validation of the A&D UA-774 (UA-767 Plus) device for self-measurement of blood pressure. Blood Pressure Monitoring 2004, 9(4):225-229
A&D UA-774Upper ArmBHS A/AIndependent2 x 30 reading memory. 4 x AA batteries, mains adaptor availableMinor protocol violation; only 2 observers used in the validation studyVerdecchia P, Angeli F, Poeta F, Reboldi GP, Borgioni C, Pittavini L & Porcellati C. Validation of the A&D UA-774 (UA-767 Plus) device for self-measurement of blood pressure. Blood Pressure Monitoring 2004, 9(4):225-229
A&D UA-779Upper ArmInternational ProtocolIndependent7 reading memory. 4 x AA batteriesLongo D, Bertolo O, Toffanin G, Frezza P & Palatini P. Validation of the A&D UA-631 (UA-774 Life Source) device for self-measurement of blood pressure and relationship between its performance and large artery compliance. Blood Pressure Monitoring 2002, 7(4):243-248
A&D UA-782 (Derivative of UA-787)Upper ArmInternational ProtocolIndependent90 reading memory, 4 x AA batteries, E-fit cuff fits arm 17-32cmLongo D, Toffanin G, Garelotto R, Zaetta V, Businaro L & Palatini P. Performance of the UA-787 oscillometrric blood pressure monitor according to the European Society of Hypertension protocol. Blood Pressure Monitoring 2003, 8(2):91-95
A&D UA-787Upper ArmInternational protocolIndependent60 reading memory. 4 x AA batteriesStandard cuff fits 22-43cmLongo D, Toffanin G, Garelotto R, Zaetta V, Businaro L & Palatini P. Performance of the UA-787 oscillometrric blood pressure monitor according to the European Society of Hypertension protocol. Blood Pressure Monitoring 2003, 8(2):91-95
A&D UA-1020Upper ArmBHS A/AIndependent4 x AA batteries or mains adaptor.  90 reading memory. D-ring or cylindrical-shaped cuffsWei-Fan Z, Yuan-Yuan K, Ming L, Yan L and Ji-Guang W.  Validation of the A&D UA-1020 upper-arm blood pressure monitor for home blood pressure monitoring according to the British Hypertension Society Protocol.  Blood Pressure Monitoring 2013, 18:177-181
A&D UA-1030T (Derivative of UA-1020)Upper ArmBHS A/AIndependent50 reading memory.  D-ring and cylindrical-shaped cuff available. Voice speaks BP readingWei-Fang Z, Yuan-Yuan K, Ming L, Yan L and Ji-Guang W.  Validation of the A&D Ua-1020 upper-arm blood pressure monitor for home blood pressure monitoring according to the British Hypertension Society Protocol.  Blood Pressure Monitoring 2013, 18:177-181
Alvita / Kinetik WellbeingTMB-1970 (Derivative of TMB986)Upper ArmInternational ProtocolIndependentWen Jun Liu, Su Gang Li, Zhe Song and Wei Gong. Validation of the TRANSTEK blood pressure monitor TMB-986 for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2015. 20:278- 280
Alvita / Kinetik WellbeingTMB - 1491-S (Derivative of
TMB-1491)
Upper ArmInternational ProtocolIndependentHuiyong Tian, Sijian Zeng, Xiaoyan Zhong, Wei Gong and Wenjun Liu Validation of Transtek blood pressure monitor TMB-1491 for self-measurement according to the European Society of Hypertension International Protocol revision 2010 Blood Pressure Monitoring, 2015, Vol 20 No 5, 280-282, doi: 10.1097/MBP.0000000000000125
Alvita / Kinetik WellbeingTMB-2083-N (Derivative Device of TMB - 1491)Upper ArmInternational ProtocolIndependentHuiyong Tian, Sijian Zeng, Xiaoyan Zhong, Wei Gong and Wenjun Liu
Validation of Transtek blood pressure monitor TMB-1491 for self-measurement according to the European Society
of Hypertension International Protocol revision 2010
Blood Pressure Monitoring, 2015, Vol 20 No 5, 280-282
Andon Health Co. LtdiHealth Track KN-550BT (Derivative of Andon KD-5917)Upper ArmInternational Protocol 2010IndependentGuo WG, Li BL, He Y, Zue YS, Wang HY, Zheng QS, Xiang DC.  Validation of the Andon KD-5917 automatic upper arm blood pressure monitor for clinic use and self-measurement according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2014, 19:242-245
Andon Health Co. LtdiHealth Feel BP5Upper ArmInternational Protocol 2010IndependentWireless device.  Bluetooth technology shares data with iOS devicesShang F, Zhu Y, Zhu Z, Liu L and Wan Y.  Validation of the iHealth BP5 wireless upper arm blood pressure monitor for sel-measurement according to the European Society of Hypertension International Protocol revision 2010
Andon Health Co. LtdiHealth Sense BP7WristInternational Protocol 2010IndependentWireless wrist device.  Bluetooth technology shares data with iOS devices.Wang Q, Zhao H, Chen W, Li N and Wan Y.  Validation of the iHealth BP7 wrist blood pressure monitor for self measurment according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2014, 19:54-57
Andon Health Co. LtdiHealth View BP7S (Derivative of iHealth Sense BP7)WristInternational Protocol 2010IndependentQingW, Huadong Z, Wan C, Ni L, Yi W.  Validation of the iHealth BP7 wrist blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2014, 19:54-57
Andon Health Co. LtdKD-5815, KD-5920,
KD-5923, (Derivative of
Andon KD-5965)
Upper ArmInternational Protocol 2010IndependentHuang J, Li Z, Li G, Liu Z. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure
monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit. 2015
Oct;20(5):283-5. doi: 10.1097/MBP.0000000000000129. PMID: 25968093.
Andon Health Co. LtdBM-091 (Derivative of KD-5915)Upper ArmInternational ProtocolIndependentQi-Fang H, JieW, Chang-Sheng S, Na-Na Z, Yan L & JL-Guang W. Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2010, 5:232-234
Andon Health Co. LtdDesa Pharma Tecnico Easy KD-558 (Derivative of Andon KD-5917)Upper ArmInternational Protocol 2010IndependentGuo WG, Li BL, He Y, Zue YS, Wand HY, Zheng QS and Ziang DC. Validation of the Andon KD-5917 automatic upper arm blood pressure monitor for clinic use and self-measurement according to the European Society of Hypertension International Protocol revision 2010.  Blood pressure Monitoring 2014, 19: 242-245
Andon Health Co. LtdiHealth BP3Upper ArmInternational Protocol 2010IndependentDock for Apple touch devices using an app of a BP monitoring system.Chen C, Shang F, Wang J, Chen J, Ji N and Wan Y. Validation of the iHealth BP3 upper-arm blood pressure monitor for clinic use and self-measurement according to the European Society of Hypertension International Protocol revision 2010.    Blood Pressure Monitoring 2012, 17:253-256
Andon Health Co. LtdiHealth Neo BP5S (Derivative of iHealth BP5)Upper ArmInternational Protocol 2010IndependentWireless device with integral cuffFujun S, Yizheng Z, Zhenlai Z, Lei L and Yi W. Validation of the iHealth BP5 wireless upper arm blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2013, 18:278-261
Andon Health Co. LtdKD-5001 (Derivative of Andon KD-5915)Upper ArmInternational ProtocolIndependentQi-Fang H, JieW, Chang-Sheng S, Na-Na Z, Yan L & JL-Guang W. Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2010, 5:232-234
Andon Health Co. LtdKD-551 (Derivative of KD-5917)Upper ArmInternational ProtocolIndependentWan-Gang Guo, Bing-Ling Li, Yong He, Yu-Sheng Xue, Hai-Yan Wang, Qiang-Sun Zheng and Ding-Cheng Xiang
Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and selfmeasurement, according to the European Society of Hypertension
International Protocol revision 2010
Blood Pressure Monitoring, 2014, 19:242–245
Andon Health Co. LtdKD - 551 (Derivative of KD5965)Upper ArmInternational ProtocolIndependentjinhua Huang, Zhijie Li, Guimei Li and Zhaoying Liu
Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring
according to the European Society of Hypertension International Protocol revision 2010;
Blood Pressure Monitoring 2015, 20:283–285
Andon Health Co. LtdKD-557 (Derivative of Andon KD-5915)Upper ArmInternational ProtocolIndependentQi-Fang H, JieW, Chang-Sheng S, Na-Na Z, Yan L & JL-Guang W. Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2010, 5:232-234
Andon Health Co. LtdKD-558 (Derivative of Andon KD-5915)Upper ArmInternational ProtocolIndependentQi-Fang H, JieW, Chang-Sheng S, Na-Na Z, Yan L & JL-Guang W. Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension Internationa Protocol. Blood Pressure Monitoring 2010, 5:232-234
Andon Health Co. LtdKD - 5810 (Derivative of
KD5917)
Upper ArmInternational ProtocolBIHSWan-Gang Guo, Bing-Ling Li, Yong He, Yu-Sheng Xue, Hai-Yan Wang, Qiang-Sun Zheng and Ding-Cheng Xiang
Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and selfmeasurement, according to the European Society of Hypertension
International Protocol revision 2010
Blood Pressure Monitoring, 2014, 19:242–245
Andon Health Co. LtdKD-5811 (Derivative of KD5917)Upper ArmInternational Protocol 2010IndependentWan-Gang Guo, Bing-Ling Li, Yong He, Yu-Sheng Xue, Hai-Yan Wang, Qiang-Sun Zheng and Ding-Cheng Xiang
Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and selfmeasurement, according to the European Society of Hypertension
International Protocol revision 2010
Blood Pressure Monitoring, 2014, 19:242–245
Andon Health Co. LtdKD-5811 (Derivative of KD5965)Upper ArmInternational Protocol 2010IndependentJinhua Huang, Zhijie Li, Guimei Li and Zhaoying Liu
Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring
according to the European Society of Hypertension International Protocol
revision 2010;
Blood Pressure Monitoring, 2015, 20:283–285
Andon Health Co. LtdKD-5815, KD-5920,
KD-5923, (Derivative of
Andon KD-5965)
Upper ArmInternational Protocol 2010IndependentHuang J, Li Z, Li G, Liu Z. Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure
monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Press Monit. 2015
Oct;20(5):283-5. doi: 10.1097/MBP.0000000000000129. PMID: 25968093.
Andon Health Co. LtdKD-5851 Upper ArmInternational Protocol 2010IndependentWu L, Jiao Y, Wang C, Chen L, Di D and Zhang H.  Validation of teh Andon KD-5851 upper arm blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2015, 20:228-231
Andon Health Co. LtdKD-5901/02/05/09/17/18/61/62/71 (All derivative models of Andon KD-5915)Upper ArmInternational ProtocolIndependentQi-Fang H, JieW, Chang-Sheng S, Na-Na Z, Yan L & JL-Guang W. Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2010, 5:232-234
Andon Health Co. LtdKD-5915Upper ArmInternational ProtocolIndependentQi-Fang H, JieW, Chang-Sheng S, Na-Na Z, Yan L & JL-Guang W. Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension Internationa Protocol. Blood Pressure Monitoring 2010, 5:232-234
Andon Health Co. LtdKD-5917Upper ArmInternational Protocol 2010IndependentGuo WG, Li BL, He Y, Xue YS, Wang HY, Zheng QS, Xiang DC.  Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement, according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2014, 19:242-245
Andon Health Co. LtdKD-595 (Derivative of Andon KD-5915)Upper ArmInternational ProtocolIndependentQi-Fang H, JieW, Chang-Sheng S, Na-Na Z, Yan L & JL-Guang W. Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2010, 5:232-234
Andon Health Co. LtdKD-5965Upper ArmInternational Protocol 2010IndependentHuang J, Li Z, Li G and Liu Z.  Validation of the Andon KD-5965 upper-arm blood pressure monitor for home blood pressure monitoring according to the Euripan Society of Hypertension International Protocol revision 2010.  Blood pressure Monitoring 2015, 20:283-285
Aseptika Activ8rlives BP3 (Derivative of Transtek TMB-1491)Upper ArmInternational Protocol 2010IndependentTian H, Zeng S, Zhong X, Gong W and Liu W. Validation of Transtek blood pressure monitor TMB-1491 for selfmeasurement according to the European Society of Hypertension International Protocol revision 2010. Blood
Pressure Monitoring 2015, 20:280-282
ASPEN/RossmaxCF55F ((Derivative of CF175)Upper ArmInternational Protocol 2010IndependentZhang L, Kang YY, Zeng WF, Li Y and Wang JG. Validation of the Rossmax CF175 upper-arm blood pressure monitor
for home blood pressure monitoring according to the European Society of Hypertension International Protocol
revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
AvitaBPM15SWristInternational Protocol 2010Independent2 x AAA batteries, 2 x 90 reading memoryKang YY, Zeng WF, Zhang L, Li Y, Wang JG.  Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring accoridng to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2014, 19:183-186
AvitaBPM17WristInternational Protocol 2010Independent2 x AAA Batteries. 2 x 90 reading memoryKang YY, Chen Q, Liu CY, Li Y & Wang JG. Validation of the AVITA BPM17 wrist blood pressure monitor for home
blood pressure monitoring according to the European Society of Hypertension International Protocol Revision
2010. Blood Pressure Monitoring 2017, 22:230-233
AvitaBPM63SUpper ArmInternational Protocol 2010Independent2 x 60 memory readings.  4 x AA BatteriesKang YY, zen WF, Liu M, Li Y and Wang JG.  Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2014, 19:46-49
Beurer BM 28Upper ArmInternational Protocol 2010IndependentValidation of the blood pressure measurement device Beurer BM 28 according to the European Society of
Hypertension International Protocol revision 2010
Cornelia Deutsch, Carsten Bramlage, Beate Botta, Ralf Krüger, Klaus Forstner, Peter Bramlage, and Beate Beime
Blood Pressure Monitoring 2021, 26:292–298
Beurer GmbHBM44Upper ArmInternational ProtocolIndependentNB  AF detection in this device does not mean that it has been validated for use in patients with AFLuders S, Kruger R, Zemmrich C, Forstner K, Sturm CD and Bramlage P.  Validation of the Beurer BM 44 upper arm blood pressure monitor for home measurement, according to the European Society of Hypertension International Protocol 2002.  Blood Pressure Monitoring 2012, 17:248-252
BPUMPBF1112Upper ArmInternational Protocol 2010Independent90 reading memoryChen Q, Kang YY, Li Y and Wang Ji-Guang. Validation of the BPUMP BF1112 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2017, 22:106-108
BraunBP VitalScan Plus 1650WristInternational ProtocolIndependent2 x AAA Alkaline BatteriesNolly H, Osso P, Nolly A, Silva M, Nolly M & Romero M. Self-measurement of blood pressure: validation of the Braun BP VitalScan Plus 1650 monitor according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2008, 13:101-106
BraunBP 3550WristInternational ProtocolIndependent2 x AAA Alkaline BatteriesIliman N, Altunkan S, Kayaturk N & Altunkan E. Validation of the Braun BP 3550 wrist blood pressure measuring device with a position sensor and an EasyClick cuff according to the International Protocol in Adults. Blood Pressure Monitoring 2007, 12:45-49
BraunBP6000, BP6100, BP6200 (All derivative Transtek TMB-986)Upper ArmInternational ProtocolIndependentDual user function. 4 x AAA batteries or AC adaptorLiu WJ, Li Su Gang, Song Z, Gong W. Validation of the Transtek blood pressure monitor TMB-986 for home blood pressure monitoring according to the Internatinal Protocol.  Blood Pressure Monitoring 2010, 15:278-280
BraunBUA5000 (Derivative of Microlife BP100 Plus)Upper ArmInternational ProtocolIndependentStergiou GS, Giovas PP, Neofytou MS, Adamopoulos DN.  Validation of the Microlife BPA100 Plus device for self-home blood pressure measurement according to the International Protocol.  Blood Pressure Monitoring: 2006, 11:157-160
CitizenCH 432BUpper ArmInternational ProtocolIndependent2 x LR03 BatteriesCotte UV, Faltenbacher VH, von Willich Werner & Bogner JR. Trial of validation of two devices for self-measurement of blood pressure according to the European Society of Hypertension International Protocol: the Citizen CH-432B and the Citizen CH-656C. Blood Pressure Monitoring 2008, 13:55-62
CitizenCH 656CWristInternational ProtocolIndependent2 x LR03 BatteriesCotte UV, Faltenbacher VH, von Willich Werner & Bogner JR. Trial of validation of two devices for self-measurement of blood pressure according to the European Society of Hypertension International Protocol: the Citizen CH-432B and the Citizen CH-656C. Blood Pressure Monitoring 2008, 13:55-62
CitizenCH-617 (Derivative of Health & Life HL-168JD)Upper ArmInternational ProtocolIndependentCheng CS, Huang QF Wang J, Zhang Y, Li Y and Wang JG.  Validation of the Health & Life HL 168JD wrist blood prressure monitor hor home blood pressure monitoring according to the international Protocol.  Blood Pressure Monitoring 2009, 14:125-127
CitizenCH-618 (Derivative of Health & Life HL-168JD)Upper ArmInternational ProtocolIndependentCheng CS, Huang QF Wang J, Zhang Y, Li Y and Wang JG.  Validation of the Health & Life HL 168JD wrist blood prressure monitor hor home blood pressure monitoring according to the international Protocol.  Blood Pressure Monitoring 2009, 14:125-127
DuronicBMP550 (Derivative of Transtek TMB-986)Upper ArmInternational ProtocolIndependent2 x 60 readings. 4 x AAA batteriesLiu WJ, Li SG, Song Z & Gong W. Validation of the Transtek blood pressure monitor TMB-986 for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2010, 15:287-280
DuronicBPM 300 (Derivative of Transtek TMB-988WristInternational ProtocolIndependent2 x AAA Alkaline BatteriesTian HY, Liu WJ, Li SG, Song Z & Gong W. Validation of the Transtek TMB-988 wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2012, 15:326-328
EuroMedixStabil-o-graphUpper ArmBHS A/A, International ProtocolIndependentInfra-red interface, AFL gentle measurement, bluetooth output. 2 x AA batteriesWesthoff TH, Schmidt S, Zidek W & van der Giet M. Validation of the Stabil-O-Graph blood pressure self-measurement device. Journal of Human Hypertension 2007, Sept, Research Letter
Fleming Medical Medicare LifeSense A1
Blood Pressure Monitor -
MD 1814 (Derivative of
TMB-1776)
Upper ArmIndependentZhonghua Liu and Liyi Chen
Validation of Transtek TMB-1776 according to European Society of Hypertension International Protocol revision
2010 in adults
Blood Pressure Monitoring 2019, 24:319-322
Fleming Medical Medicare Lifesense A5 Blood Pressure Monitor - MD1806 (Derivative of TMB-1776)Upper ArmIndependentLiu, Zhonghua; Chen, Liyi. Validation of Transtek TMB-1776 according to European Society of Hypertension
International Protocol revision 2010 in adults. Blood Pressure Monitoring 2019. 24(6):319-322
GrandwayG.LAB MD2200WristBHS A/A, International Protocol 2010Independent2 x 120 reading memoryLiu ZY, Zhang QH, Ye XL, Liu DP, Cheng K, Zhang CH and Wan Y.  Validation of the G.LAB MD2200 wrist blood pressure monitor according to the European Society of Hypertension, the British Hypertension Society and the International Organization for Standardization Protocols.  Blood Pressure Monitoring 2017, 22:101-104
GrandwayMD2680Upper ArmIndependent4 x AA Batteries. Large Cuff up to 44cm availableGuo YF, Zhang XQ, Fu JL, Zhang X, Shan HZ, Shi N &Yan LQ. Validation of the G.LAB MD2680 digitial Automatic
blood pressure monitor according to international protocols. Blood Pressure Monitoring 2017, 22 221-225
GrandwayMD2301Upper ArmInternational Protocol 2010IndependentChen W, Zeng ZL, Bing S, Li LY, Wang R and Wan Y.  Validation of the Grandway MD2301 digital automatic blood pressure monitor according to the European Society of Hypertension International Protocol.  Blood Pressure Monitoring 2016, 21:259-261
Grandway MD2231 WristIndependent2 x AAA Alkaline BatteriesJiao Y, Guan Q, Wu L, Wang C & Cao L. Validation of the G.LAB MD2231 digital automatic wrist blood pressure
monitor according to multiple protocols. Blood Pressure Monitoring 2017, 22:226-229
HartmannTensoval Duo ControlUpper ArmBHS A/A, International ProtocolIndependentde Greef A, Arora J, Hervey S, Liu B & Shennan A. Accuracy assessment of the Tensoval duo control according to the British and European Hypertension Societies’ standards. Blood Pressure Monitoring 2008, 13:111-116
HartmannTensoval Duo Controll IIUpper ArmBHS A/A, International ProtocolIndependentDevice uses a combination of auscultatory and oscillometric technology to measure BP. 4 x AA batteriesAF detection in this device does not mean that it will accurately measure BP in AF patients.de Greef AM, Shennan AH.  Validation of the Tensoval Duo Control II blood pressure monitor for clinic use and self-measurement according to the British Hypertension Society Protocol and the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2013, 18-161-166
Health & LifeHL888HAUpper ArmBHS A/AIndependent4 x AA batteriesMinor protocol violation; only 2 observers used in the validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Health & LifeAI-H971 (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependentAF detection in this device does not mean that it will accurately measure BP in AF patients. Minor protocol violation: only 2 observers used in validation studyde Greef A & Shennan A.  The Health & Life device (HL999HA): accuracy assessment in an adult population according to the British Hypertension Society protocol.  Blood Pressure Monitoring 2007, 12:107-111
Health & LifeBPM4 (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependentMinor protocol violation:  only 2 observers used in validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Health & LifeBPM4TL (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependentMinor protocol violation:  only 2 observers used in validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Health & LifeHL158MA, KA (Derivative of Health & Life HL168JD)WristInternational ProtocolIndependentSheng C, Huang Q, Wang J, ZhangY, Li Y & Wang J. Validation of the Health & Life HL 168JD wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2009, 14:125-127
Health & LifeHL 168JDWristInternational ProtocolIndependentSheng C, Huang Q, Wang J, ZhangY, Li Y & Wang J. Validation of the Health & Life HL 168JD wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2009, 14:125-127
Health & LifeHL168KB, ZA (Derivative of Health & Life HL168JD)WristInternational ProtocolIndependentAF detection in this device does not mean that it will accurately measure BP in AF patients.Sheng C, Huang Q, Wang J, ZhangY, Li Y & Wang J. Validation of the Health & Life HL 168JD wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2009, 14:125-127
Health & LifeHL858BA, BC, HA, GA (Derivatives of Health & Life HL888HA)Upper ArmBHS A/AIndependentAF detection in this device does not mean that it will accurately measure BP in AF patients. Minor protocol violation: only 2 observers used in validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Health & LifeHL858EF,DF,CF (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependentAF detection in this device does not mean that it will accurately measure BP in AF patients. Minor protocol violation: only 2 observers used in validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Health & LifeHL858DK (Derivative of HL888HA)Upper ArmBHS A/AIndependentde Greef A and Shennan A. The Health & Life device (HL888HA): Accuracy assessment in an adult population according to the British Hypertension Society Protocol.  Blood Pressure Monitoring 2007, 12@107-111
Health & LifeHL868BAUpper ArmInternational ProtocolIndependentChen HE, Cui Y, Sheng CS, Li LH, Li Y & Wang JG. Validation of the Health & Life HL 866BA blood pressure monitor for home blood pressue monitoring according to the European Society of Hypertension Internationa protocol. Blood Pressure Monitoring 2008, 113:305-308
Health & LifeHL868EDUpper ArmIndependentValidation of the HL868ED upper-arm blood pressure monitor for clinical use and self-measurement according
to the British Hypertension Society Protocol. Wei Zhang, Lei L, Yan Li and Ji-Guang Wang. Blood Pressure
Monitoring 2019, 24:203–207
Health & LifeHL868 NF, ZA, ZB (Derivatives of Health & Life HL 888HA)Upper ArmBHS A/AIndependentAF detection in this device does not mean that it will accurately measure BP in AF patients. Minor protocol violation: only 2 observers used in validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Health & LifeHL 888HC (Derivative of Health & Life HL 888HA)Upper ArmBHS A/AIndependentMinor protocol violation:  only 2 observers used in validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Health & LifeWGNBPA-730,740,750 (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependentAF detection in this device does not mean that it will accurately measure BP in AF patients. Minor protocol violation: only 2 observers used in validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Health & LifeWGNBPW-710,720 (Derivative of Health & Life HL168JD)WristInternational ProtocolIndependentSheng C, Huang Q, Wang J, ZhangY, Li Y & Wang J. Validation of the Health & Life HL 168JD wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2009, 14:125-127
Health AssureHL158JA, 158JT, 158SA, 158SK, 158ST (All derivatives of Health & Life HL168JD)WristInternational ProtocolIndependentChang-Sheng S, Qi-Fang H, Jie W, Yi Z, Yan L and Ji-Guang W.  Validation of the Health & Life HL169JD wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol.  Blood Pressure monitoring 2009, 14:125-127
Health AssureHL 858JA, 858JT, 858SA, 858SK, 858ST, 959JA (All derivatives of Health & Life HL888HA)Upper ArmBHS A/AIndependentde Greef AM and Shennan AH.  The Health & Life device (HL888HA):  Accuracy assessment in an adult population according to the British Hypertension Society Protocol.  Blood Pressure Monitoring 2007, 12:107-111
HoMedicsBPW 1000 (Derivative of Transtek TMB-988)WristInternational ProtocolIndependentTian HY, Liu WJ, Li SG, Song Z & Gong W. Validation of the Transtek blood pressure monitor TMB-988 for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2010, 15:326-328.
HoMedicsBPA 2000 (Derivative of Transtek TMB 986)Upper ArmInternational ProtocolIndependent4 x AA batteries, AC AdapterLiu WJ, Li SG, Song Z & Gong W. Validation of the Transtek blood pressure moniotor TMB-986 for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2010, 15:279-280.
HoMedics360-EU (Derivative of
Oregon Scientific BPU 330)
Upper ArmInternational ProtocolIndependent6 x 30 reading memoryLi L, Zhang X, Yan C & Liang Q. Validation of the Oregon Scientific BPU 330 for self-monitoring of blood pressure according to the International Protocol. Vascular Health and Risk Management 2008, 4(5):1121–1125
HoMedicsBPA-3000 (Derivative of Transtek TMB-986)Upper ArmInternational Protocol Independent4 x AAA batteries, AC adapterLiu WJ, Li SG, Song Z & Gong W. Validation of the Transtek blood pressure moniotor TMB-986 for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2010, 15:279-280.
HoMedicsSalter BPA-8200-EU (Derivative of Andon KD-5915)Upper ArmInternational ProtocolIndependent2 x 60 memory readingHuang QF, Wang J, Sheng CS, Zhang NN, Li Y and Wang JG.  Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.  Blood Pressure Monitoring 2010, 15:232-234
HoMedicsSalter BPA-9200-GB (Derivative of Andon KD-5915)Upper ArmInternational ProtocolIndependent2 x 60 memory readingHuang QF, Wang J, Sheng CS, Zhang NN, Li Y and Wang JG.  Validation of the Andon KD-5915 blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol.  Blood Pressure Monitoring 2010, 15:232-234
HonsunLD30 (Derivative of LD578)Upper ArmInternational ProtocolIndependentZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for
home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood
Pressure Monitoring 2009, 14:128
HonsunLD-520, 522, 526, 528, 530, 532, 533, 568, 582, 586N, 587 (Derivative of Honsun LD-578)Upper ArmInternational ProtocolIndependent4 x AA batteriesZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2009, 14:128
Honsun/MedisanaLD-528 (Derivative of Honsun LD-578)Upper ArmInternational ProtocolIndependentZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2009, 14:128
Honsun / SuresignLD 578Upper ArmInternational ProtocolIndependent30 reading memoryZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2009, 14:128
Honsun / SuresignLD 3 (Derivative of LD 578)Upper ArmInternational ProtocolIndependent90 reading memory. 4 x AA batteriesZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2009, 14:128-131
Honsun / SuresignLD30 (Derivative of LD 578)Upper ArmInternational ProtocolIndependent30 reading memoryZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2009, 14:128
Honsun / SuresignLD-588 (Derivative of LD-578)Upper ArmInternational ProtocolIndependentZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2009, 14:128-131
Honsun/MediProMP-BP-BPM (Derivative of LD533)Upper ArmInternational ProtocolIndependentYi Zhang, Jie Wang, Qi-Fang Huang, Chang-Sheng Sheng, Yan Li And Ji-Guang Wang
Validation of the Honsun LD-533 Blood Pressure Monitor For Home Blood Pressure Monitoring According to the
European Society Of Hypertension International Protocol
Blood Pressure Monitoring
June 2009-volume 14-issue 3-pp 128-131
InBodyBP 170Upper ArmInternational ProtocolIndependentKollias A, Anagnostopoulos I, Gravvani A, Stambolliu E, Bountzona I, Ariadni
Menti A and Stergiou G. Validation of the InBody BP170 oscillometric home blood pressure monitor in general
population according to the Association for the Advancement of Medical Instrumentation/European Society of
Hypertension/ International Organization for Standardization Universal Standard. Blood Pressure Monitoring 2020,
25:50–52
KesslerKS551 (Derivative of
Rossmax ME701)
Upper ArmBHS A/A, International ProtocolIndependentdeGreef A & Shennan AH. The Rossmax (ME701 series) upper arm device: accuracy assessment in an adult population according to the International and the British Hypertension Society protocols. Blood Pressure Monitoring 2008, 13:43-48
Kinetik Wellbeing TMB-1970 (Derivative of
TMB-986)
Upper ArmIndependent90 reading memory, 4 x AAA battery included 22-42cm cuff included, automatic inflation, one button operationWen Jun Liu, Su Gang Li, Zhe Song and Wei Gong. Validation of the TRANSTEK blood pressure monitor TMB-986
for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2015.
20:278-280
Kinetik Wellbeing TMB-2080 (Derivative of
TMB-1491)
Upper ArmIndependent2 x 90 reading memory (plus guest mode) 4 x AAA battery included22-42cm cuff included, Irregular heartbeat detectio, Automatic
inflation, One button operation
Huiyong Tian, Sijian Zeng, Xiaoyan Zhong, Wei Gong and Wenjun Liu. Validation of Transtek blood pressure
monitor TMB-1491 for self-measurement according to the European Society of Hypertension International
Protocol revision 2010. Blood Pressure Monitoring 2015. 20:280-282
Kinetik Wellbeing WBP1 (Derivative of
Transtek TMB-1491)
Upper ArmIndependent90 Reading Memory, 4 x AAA battery included22-42cm cuff included, Irregular heartbeat detectio, Automatic
inflation, One button operation
Tian H, Zeng S, Zhong X, Gong W and Liu W. Validation of Transtek blood pressure monitor TMB-1491 for selfmeasurement according to the European Society of Hypertension International Protocol revision 2010. Blood
Pressure Monitoring 2015, 20:280-282
Kinetik Wellbeing TMB - 2088 (Derivative of
TMB - 986)
Upper ArmIndependent2 x 250 reading memory (plus guest mode), 4 x AA battery included22-42cm cuff included, movement
detection indicator, cuff wrap detection, BP trend display, Buetooth sync results, irregular heartbeat detection,
averages readings, WHO indicator, automatic inflation, one button operation
Wen Jun Liu, Su Gang Li, Zhe Song and Wei Gong. Validation of the TRANSTEK blood pressure monitor TMB-986
for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2015,
20:278-280
Kinetik Wellbeing WPB3 (Derivative of TMB988)WristIndependent2 x 60 reading memory, 2 x AAA battery included13.5-21.5cm cuff, irregular heartbeat detection, averages
readings automatic inflation, one button operation, positioning sensor and WHO indicator
Hui Yong Tian, Wen Jun Liu, Su Gang Li, Zhe Song and Wei Gong
Validation of the TRANSTEK TMB-988 wrist blood pressure monitor for home blood pressure monitoring
according to the International Protocol
Blood Pressure Monitoring, 2010, 15: 326-328
KingyieldBP101HUpper ArmInternational ProtocolIndependentZeng WF, Huang QF, Sheng CS, Li Y & Wang JG. Validation of the Kingyield BP101H blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood Pressure Monitoring 2010, 15:329-331
Little Doctor Electronic (Nantong)LD12 (Derivative of SCIAN LD735)Upper ArmInternational Protocol 2010IndependentDD info from HonsunKang YY, Chen Q, Li Y and Wang JG. Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood
pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood
Pressure Monitoring 2016, 21:255-258
Little Doctor Electronic (Nantong)LD51, LD51U, LD51A, LD51S
(Derivative of Honsun LD-578)
Upper ArmInternational ProtocolIndependentModel LD51S has spoken voice facilityDD info from HonsunZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for
home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood
Pressure Monitoring 2009, 14:128
Little Doctor Electronic (Nantong)LD-521 (Derivative of Honsun
LD-578)
Upper ArmInternational ProtocolIndependentDD info from HonsunZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for
home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood
Pressure Monitoring 2009, 14:128
Little Doctor Electronic (Nantong)LD-521A (Derivative of LD-578)Upper ArmInternational ProtocolIndependentZhang Y, Wang J, Huang Q, Sheng C, Li Y & Wang J. Validation of the Honsun LD-578 blood pressure montitor for
home blood pressure monitoring according to the European Society of Hypertension International Protocol. Blood
Pressure Monitoring 2009, 14:128
Maestro Innovations CorporationHealth Assure HL158JA, 158JT, 158SA, 158SK, 158ST (All derivatives of Health & Life HL168JD)WristInternational Protocol IndependentChang SS, Qi-Fang H, Jie W, Yi Z, Yan L and Ji-Guang W.  Validation of the Health & Life HL168JD wrist blood pressure monitor for home blood pressure monitoring according to the international protocol.  Blood Pressure Monitoring 2009, 14:125-127
Maestro Innovations CorporationHealth Assure HL858JA, 858JT, 858SA, 858SK, 858ST, 959JA (All derivatives of Health & Life HL888HA)Upper ArmBHS A/AIndependentde Greef AM and Shennan AH.  The Health & Life device (HL888HA):  Accuracy assessment in an adult population according to the British Hypertension Society Protocol.  Blood Pressure Monitoring 2007, 12:107-111
Medinox Ltd MX86005 (KD-5923) (Derivative
of KD-5917)
Upper ArmInternational Protocol 2010 IndependentWan-Gang Guo, Bing-Ling Li, Yong He, Yu-Sheng Xue, Hai-Yan Wang, Qiang-Sun Zheng and Ding-Cheng Xiang
Validation of the Andon KD-5917 automatic upper arm blood pressure monitor, for clinic use and self-measurement,
according to the European Society of Hypertension International Protocol revision 2010
Blood Pressure Monitoring; 2014, 19:242–245
Medipro/RossmaxMedicare 100fUpper ArmInternational Protocol 2010IndependentYi J, Pan F, Yu X, Zhao H, Shang F & Xu Y. Validation of the Medipro Medicare 100f upper arm blood pressure monitor for self-measurement, according to the European Society of Hypertension International Protocol Revision 2010. Blood Pressure Monitoring 2011, 16:197-199
MedisanaMTP PlusUpper ArmInternational Protocol 2010 IndependentErdem E, Aydogudu T & Akpolat T. Validation of the Medisana MTP Plus upper arm blood pressure monitor for self-measurement according to the European Society of Hypertension International Protocol revision 2010
MicrolifeBPA3 (Derivative of BP
3BTO-A)
Upper ArmIndependentValidation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring device according to a modified
British Hypertension Society protocol. Cuckson AC, Reinders A, Shabeeh H, Shennan AH. Blood Pressure
Monitoring 2002, 7 (6): 319-324
MicrolifeBP3AG1 (Derivative of 3BTO-AUpper ArmBHS A/AIndependentLast reading memory. 4 x AA batteries, mains adaptor availableMinor protocol violation; only 2 observers used in the validation studyCuckson AC, Reinders A Shabeeh H & Shennan A. Validation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring device according to a modified British Hypertension Society protocol. Blood Pressure Monitoring 2002, 7(6):319-324
MicrolifeW2 SlimWristIndependentBing S, Chen K, Hou H, Zhang W, Li L, Wei J, Shu C and Wan Y. Validation of the Microlife BP A200 Comfort and
W2 Slim automated blood pressure monitors in a general adult population according to the European Society
of Hypertension and the ANSI/AAMI/ISO 81060-2:2013 protocols. Blood Pressure Monitoring 2016, 21:118-123
MicrolifeA100 (Derivative of Microlife 3BTO-A)Upper ArmBHS A/AIndependentLast reading memory, 4 x AA batteriesArrhythmia detection in this device does not mean that this device has been validated for use in patients with arrhythmia. Minor protocol violation; only 2 observers used in the validation study. Also validated using a standard cuff of a range of arm circumferencesCuckson AC, Reinders A Shabeeh H & Shennan A. Validation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring device according to a modified British Hypertension Society protocol. Blood Pressure Monitoring 2002, 7(6):319-324. Bonso E, dorigatti F & Palatini P. Accuracy of th BP A100 blood pressure measruing device coupled with a singl cuff with standard-sized bladder over a wide range of arm circumferences. Blood Pressure Monitoring 2009, 14:216-219
MicrolifeBP A100 PlusUpper ArmInternational ProtocolIndependent200 reading memory. 4 x AA batteries mains adaptor availableStergiou GS, Giovas PP, Neofytou MS & Adamopoulos DN. Validation of the Microlife BP A100 Plus device for self-home blood pressure measurement according to the International Protocol. Blood Pressure Monitoring 2006, 11(3):157-160
MicrolifeBP A200 ComfortUpper ArmIndependentBing S, Chen K, Hou H, Zhang W, Li L, Wei J, Shu C and Wan Y. Validation of the Microlife BP A200 Comfort and
W2 Slim automated blood pressure monitors in a general adult population according to the European Society
of Hypertension and the ANSI/AAMI/ISO 81060-2:2013 protocols. Blood Pressure Monitoring 2016, 21:118-123
MicrolifeBP B1 Classic(Derivative of BP B3 AFIB)Upper Arm ANSI/AAMI/ISO
81060-2:2019 protocol.
IndependentBeate Beime, Carsten Bramlage, Ralf Kruger, Cornelia Deutsch, Gesine Van Mark, Peter Bramlage, Beate Botta.Validation of
the Microlife BP B3 AFIB upper arm blood pressure monitor in adults and adolescents according to the ANSI/AAMI/ISO
81060-2:2019 protocol.2021 Aug 1;26(4):299-304.
MicrolifeBP B2 Basic(Derivative
of BP B3 AFIB)
Upper Arm ANSI/AAMI/ISO
81060-2:2019 protocol.
IndependentBeate Beime, Carsten Bramlage, Ralf Kruger, Cornelia Deutsch, Gesine Van Mark, Peter Bramlage, Beate Botta.Validation of
the Microlife BP B3 AFIB upper arm blood pressure monitor in adults and adolescents according to the ANSI/AAMI/ISO
81060-2:2019 protocol.2021 Aug 1;26(4):299-304.
MicrolifeWatchBP Home -
Pregnancy Only
Upper ArmIndependentValidated for home use in pregnancy onlyClark K, Snowball O, Nzelu D, Kay P, Kametas A. Validation of the Microlife WatchBP Home blood pressure
device in pregnancy for medium and large arm circumferences. Blood Pressure Monitoring 2018, 23:171-174
MicrolifeB3AFIBUpper ArmANSI/AAMI/ISO 81060-2:2019IndependentBeime, Beate; Bramlage, Carsten; Krüger, Ralf; Deutsch, Cornelia; van Mark, Gesine; Bramlage, Peter; Botta, Beate
Validation of the Microlife BP B3 AFIB upper arm blood pressure monitor in adults and adolescents according to the
ANSI/AAMI/ISO 81060-2:2019 protocol
Blood Pressure Monitoring: August 2021 - Volume 26 - Issue 4 - p 299-304
doi: 10.1097/MBP.0000000000000530
MicrolifeBPA2 Basic (Derivative of BP
3BTO-A)
Upper ArmBHS A/AIndependentValidation of the Microlife BP 3BTO-A oscillometric blood pressure monitoring device according to a modified British
Hypertension Society protocol. Cuckson AC, Reinders A, Shabeeh H, Shennan AH. Blood Pressure Monitoring 2002, 7
(6): 319-324
MicrolifeW2 SlimWristInternational Protocol 2010IndependentBing S, Chen K, Hou H, Zhang W, Li L, Wei J, Shu C and Wan Y.  Validation of the Microlife BP A200 Comfort and W2 Slim automated blood pressure monitors in a general adult population according to the European Society of Hypertension and the ANSI/AAMI/ISO 81060-2:2013 protocols.  Blood Pressure Monitoring 2016, 21:118-123
MicrolifeWatchBP Home A (BP3MX1-3)
(Derivative Device of BP
B3AFIB)
Upper ArmANSI/AAMI/ISO 81060-2:2019IndependentThe derivative device (Watch Home A) only to be supplied with this (22-42cm conical) cuffBeime, Beate; Bramlage, Carsten; Krüger, Ralf; Deutsch, Cornelia; van Mark, Gesine; Bramlage, Peter; Botta, Beate
Validation of the Microlife BP B3 AFIB upper arm blood pressure monitor in adults and adolescents according to the
ANSI/AAMI/ISO 81060-2:2019 protocol
Blood Pressure Monitoring: August 2021 - Volume 26 - Issue 4 - p 299-304
doi: 10.1097/MBP.0000000000000530
Omron HealthcareHEM - 7121J-E (Derivative of HEM-7130)Upper ArmInternational ProtocolIndependentTakahashi H, Yoshika M, Yokoi T.
Validation of three automatic devices for the self·measurement of blood pressure According to the European
Society of Hypertension International Protocol revision 2010 the Omron HEM-7130, HEM·7320F, and
HEM·7500F
Blood Pressure Monitoring 2015: 20:92-97
Omron HealthcareHEM - 7143T -EBK
(Derivative of HEM-7130)
Upper ArmInternational ProtocolIndependentTakahashi H, Yoshika M, Yokoi T.
Validation of three automatic devices for the self·measurement of blood pressure According to the European
Society of Hypertension International Protocol revision 2010 the Omron HEM-7130, HEM·7320F, and
HEM·7500F
Blood Pressure Monitoring 2015: 20:92-97
Omron HealthcareHEM-7155-E-M3 Comfort
(Derivative of BP760N
(HEM-7320-Z))
Upper ArmIndependentHakuo Takahashi, Masamichi Yoshika, and Toyohiko Yokoi Validation of two automatic devices for the self-measurement of blood pressure according to the ANSI/AAMI/ISO81060-2:2009 guidelines: the Omron BP765 (HEM-7311-ZSA) and the Omron BP760N (HEM-7320-Z) Vascular Health and Risk Management, 2015; 11: 49–53
Omron HealthcareHEM-7155T-EBK-M4 Intelli
IT (Derivative of BP760N
(HEM-7320-Z))
Upper ArmIndependentHakuo Takahashi, Masamichi Yoshika, and Toyohiko Yokoi
Validation of two automatic devices for the self-measurement of blood pressure according to the
ANSI/AAMI/ISO81060-2:2009 guidelines: the Omron BP765 (HEM-7311-ZSA) and the Omron
BP760N (HEM-7320-Z)
Vascular Health and Risk Management, 2015; 11: 49–53
Omron HealthcareM1 (HEM-4030-C-E (Derivative of M1 Plus (HEM-4011C-E)) Upper ArmInternational ProtocolIndependent14 reading memory, 2 AAA batteriesBelghazi J, El Feghali RN, Moussalem T, Rejdych M & Asmar R. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension. Vascular Health & Risk Management 2007, 3(4):1-12
Omron HealthcareM2 (HEM-7121-E)
(Derivative of Omron HEM7130)
Upper ArmIndependentHEM model number. This is not the same as the M2 (HEM-7117-E)Takahashi H, Yoshika M and Yokoi T. Validation of three automatic devices for the self-measurement of blood
pressure according to the European Society of Hypertension International Protocol revision 2010: the Omron
HEM-7130, HEM-7320F and HEM-7500F. Blood Pressure Monitoring 2015, 20:92-97
Omron HealthcareM2 (HEM-7117) (Derivative of M3-I (HEM-7051-E))Upper ArmInternational Protocol Independent21 reading memoryAsmar R, Khabouth J, Topouchian J, El Faghali R & Mattar J. Validation of three automatic devices for self-measurement of blood pressure according to the International Protocol: The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM-7102-E) and the Omron R3-I Plus (HEM-6022-E). Blood Pressure Monitoring 2010, 15:40-54
Omron HealthcareM2 Basic (HEM-7116-E) (Derivative of M3-I (HEM-7051-E))Upper ArmInternational ProtocolIndependentPrevious memory onlyAsmar R, Khabouth J, Topouchian J, El Faghali R & Mattar J. Validation of three automatic devices for self-measurement of blood pressure according to the International Protocol: The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM-7102-E) and the Omron R3-I Plus (HEM-6022-E). Blood Pressure Monitoring 2010, 15:40-54
Omron HealthcareM2 Basic (HEM-7120-E)
(Derivative of Omron HEM7130)
Upper ArmIndependentThis is not the same as the M2 Basic (HEM-7116-E) deviceTakahashi H, Yoshika M, Yokoi T. Validationof three automatic devices for the self-measurement of blood
pressure according to the European Society of Hypertension International Protocol revision 2010: the Omron
HEM-7130, HEM-7320F and HEM-7500F. Blood Pressure Monitoring 2015, 20:92-97
Omron HealthcareM2 Compact (HEM-7102-E)Upper ArmInternational ProtocolIndependent14 Reading memoryAsmar R, Khabouth J, Topouchian J, El Faghali R & Mattar J. Validation of three automatic devices for self-measurement of blood pressure according to the International Protocol: The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM-7102-E) and the Omron R3-I Plus (HEM-6022-E). Blood Pressure Monitoring 2010, 15:49–54
Omron HealthcareM3 (HEM-7200-E)Upper ArmInternational ProtocolIndependentCuff wrapping guide indicator, 60 reading memoryTopouchian J, Agnoletti D, Blacher J, Youssef A, Ibanez I, Khabouth J, Khawaja S, Beaino L, Asmar R.  Validation of four automatice cevices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension.  Vascular Health & Risk Management 2011:7 709-717
Omron HealthcareM3 Comfort (HEM-7134-E)Upper ArmIndependentAlso Validated for home use in pregnancy and pre-eclampsia according to the 'Universal Protocol'Takahashi H. Validation of home blood pressure monitoring devices Omron EVOLV (HEM-7600T-E), HEM-9210T
and M3 Comfort (HEM-7134-E) according to European Society of Hypertension International Protocol (ESH_IP)
Revision 2010. J. Clin. Physiol, Vol.48, No. 1, 2018
Topouchian J, Hakobyan Z, Asmar J, Gurgenian S, Zelveian P, Asmar R. Clinical accuracy of the Omron M3
Comfort and the Omron Evolv for self-blood presure measurements in pregnancy and pre-eclampsia -
validation according to the Universal Standard Protocol. Vascular Health & Risk Management 2018:14 189-197
Omron HealthcareM3 Intellisense (HEM-70-51-E)Upper ArmInternational ProtocolIndependentIntellisense technology ensures that cuff is inflated to a comfortable level, detects irregular pulseAsmar R, Khabouth J, Topouchian J, El Faghali R & Mattar J. Validation of three automatic devices for self-measurement of blood pressure according to the International Protocol: The Omron M3 Intellisense (HEM-7051-E), the Omron M2 Compact (HEM-7102-E) and the Omron R3-I Plus (HEM-6022-E). Blood Pressure Monitoring 2010, 15:40-54
Omron HealthcareRS2 (HEM-6121-E) (Derivative of Omron RS3 (HEM-6130-E))WristInternational Protocol IndependentTakahashi H, Yoshika M, and Yokoi T. Validation of Omron RS8, RS6 and RS3 Home blood pressure monitoring
devices, in accordance with the European Society of Hypertension International Protocl revision 2010. Blood
Pressure Monitoring 2013, 9:265-272
Omron HealthcareRS6 (HEM-6221-E)WristInternational ProtocolIndependent90 reading memoryPositioning sensor. 2 x LR03 batteries.Takahashi H, Yoshika M, Yokoi T. Validation of Omron RS8, RS6 and RS3 home blood pressure monitoring
devices, in accordance with the European Society of Hypertension International Protocol 2010. Vascular Health
and Risk Management 2013:9 265-272
Omron HealthcareEVOLV (HEM-7600T-E) Upper ArmInternational ProtocolIndependentBluetooth function compatible with smart devicesAlso Validated for home use in pregnancy and pre-eclampsia according to the 'Universal Protocol'Takahashi H. Validation of home blood pressure monitoring devices Omron EVOLV (HEM-7600T-E), HEM-9210T and
M3 Comfort (HEM-7134-E) according to European Society of Hypertension International Protocol (ESH_IP) Revision
2010. J. Clin. Physiol, Vol.48, No. 1, 2018
Topouchian J, Hakobyan Z, Asmar J, Gurgenian S, Zelveian P, Asmar R. Clinical accuracy of the Omron M3 Comfort
and the Omron Evolv for self-blood presure measurements in pregnancy and pre-eclampsia - validation according
to the Universal Standard Protocol. Vascular Health & Risk Management 2018:14 189-197
Omron HealthcareHEM - 7360-E- M6 Comfort
(Derivative Device of BP760N
(HEM7320-Z))
Upper ArmANSI/AAMI/ISO81060-2:2009IndependentHakuo Takahashi, Masamichi Yoshika, and Toyohiko Yokoi
Validation of two automatic devices for the self-measurement of blood pressure according to the
ANSI/AAMI/ISO81060-2:2009 guidelines: the Omron BP765 (HEM-7311-ZSA) and the Omron
BP760N (HEM-7320-Z)
Vascular Health and Risk Management, 2015; 11: 49–53
Omron HealthcareHEM-7361T-EBK-M7 Intelli IT
(Derivative of BP760N (HEM7320-Z))
Upper ArmANSI/AAMI/ISO81060-2:2009IndependentHakuo Takahashi, Masamichi Yoshika, and Toyohiko Yokoi
Validation of two automatic devices for the self-measurement of blood pressure according to the
ANSI/AAMI/ISO81060-2:2009 guidelines: the Omron BP765 (HEM-7311-ZSA) and the Omron
BP760N (HEM-7320-Z)
Vascular Health and Risk Management, 2015; 11: 49–53
Omron HealthcareHEM - 7530T-E3 - OMRON Complete (Derivative of HEM - 7311 -ZSA (BP765))Upper ArmANSI/AAMI/ISO81060-2:2009IndependentHakuo Takahashi, Masamichi Yoshika, and Toyohiko Yokoi
Validation of two automatic devices for the self-measurement of blood pressure according to the
ANSI/AAMI/ISO81060-2:2009 guidelines: the Omron BP765 (HEM-7311-ZSA) and the Omron
BP760N (HEM-7320-Z)
Vascular Health and Risk Management, 2015; 11: 49–53
Omron HealthcareHEM-9601T NightviewWristANSI/AAMI/ISO81060-2:2009IndependentAutomatically measures silently night-time blood pressure.
Clinically validated accuracy in different positions, even if the wrist rotates during sleep
Mitsuo Kuwabara, Kanako Harada, Yukiko Hishiki, Takayoshi Ohkubo, Kazuomi Kario, Yutaka Imai
Validation of a wrist-type home nocturnal blood pressure monitor in the sitting and supine position according to
the ANSI/AAMI/ISO81060-2:2013 guidelines: Omron HEM-9601T
J Clinical Hypertension. 2020;00:1-9
DOI: 10.1111/jch.13864
Omron HealthcareM6 (HEM-7001-E) Derivative of Omron 705 IT (HEM759-E)Upper ArmBHS A/A, International ProtocolIndependent4 x AA batteriesAltunkan S, Illiman N, Kayaturk N & Altunkan E. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults. Blood Pressure Monitoring 2007, 12:219-225.
Omron HealthcareM6 Comfort (HEM-7221-E) (Derivative of M7 (HEM-780-E))Upper ArmBHS A/A, International ProtocolIndependentOne size cuff 22-42cm, 4 x AA batteries, AC mains adapter availableBelghazi J, El Feghali RN, Moussalem T, Rejdych M & Asmar R. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension. Vascular Health & Risk Management 2007, 3(4):1-12. Coleman A, Steel S, Freeman P de greef A & Shennan A. Validation of the Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society. Blood Pressure Monitoring 2008, 1349-54
Omron HealthcareM7 (HEM-780-E)Upper ArmBHS A/A, IndependentOne-size cuff 22-42cm, 4 x AA batteries, AC mains adapter availableAlso validated for use in obese adults and pregnancy - See Specialist Use listColeman A, Steel S, Freeman P, de Greeff A & shennan A. Validation of the Omron M7 (HEM-780-E) oscillometric blood pressure monitoring device according to the British Hypertension Society . Blood Pressure Monitoring 2008, 13:49-54.
Omron HealthcareM10-IT (HEM-7080IT-E) (Derivative of M6 Comfort (HEM-7000-E))Upper ArmInternational ProtocolIndependent4 x AA batteries mains adaptor availableBelghazi J, El Feghali RN, Moussalem T, Rejdych M & Asmar R. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension. Vascular Health & Risk Management 2007, 3(4):1-12.
Omron HealthcareRS8 (HEM-6310F-E)WristInternational Protocol 2010IndependentPositioning sensor, 2 x LR03 batteries, 100 reading memoryTakahahi H, Yoshika M, Yokoi T.  Validation of Omron RS8, RS6 and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol revision 2010.  Vascular Health and Risk Management 2013:9 265-272
Omron HealthcareBP760N HEM-7320-ZUpper Arm ANSI /AA MI/IS O81060-2:2009IndependentTakahashi H, Yoshika M, Yokoi T. Validation of two automatic devices for the self-measurement of blood pressure
according to the ANSI /AA MI/IS O81060-2:2009 guidelines: the Omron BP765 (HEM-7311-ZSA ) and the Omron
BP760N (HEM-7320-Z). Vascular Health and Risk Management 2015:11 49–53
Omron HealthcareBP765 HEM-7311-ZSAUpper Arm ANSI /AA MI/IS O81060-2:2009IndependentTakahashi H, Yoshika M, Yokoi T. Validation of two automatic devices for the self-measurement of blood pressure
according to the ANSI /AA MI/IS O81060-2:2009 guidelines: the Omron BP765 (HEM-7311-ZSA ) and the Omron
BP760N (HEM-7320-Z). Vascular Health and Risk Management 2015:11 49–53
Omron HealthcareHEM-7120Upper ArmInternational Protocol 2010IndependentPuhong Zhanga,b, Xi Lic, Zhe Fanga, Yanling Luc, Jingchen Cuid, Xin Dua and Rong Huc
Smartphone application-supported validation of three automatic devices for self-measurement of blood pressure
according to the European Society of Hypertension International Protocol revision 2010: the Omron HEM-7120,
Yuwell YE680A and Cofoe KF-65B
Blood Pressure Monitoring 2021, 26:435–440
Omron HealthcareHEM-9200TUpper ArmIndependentHakuo Takahashi, Kanako Saito, Nobuki Yakura
Validation of Omron HEM-9200T, a home blood pressure monitoring device for the upper arm, according to the
American National Standards Institute/Association for the Advancement of Medical Instrumentation/International
Organization for Standardization
81060-2:2013 protocol
Journal of Human Hypertension
https://doi.org/10.1038/s41371-021-00536-1
Omron HealthcareM2 (HEM-7121-E) (Derivative of Omron HEM-7130)Upper ArmInternational Protocol 2010IndependentNOTE: HEM model number.  This is not the same as the M2 (HEM-7117-E)Takahashi H, Yoshika M and Yokoi T.  Validation of three automatic devices for the self-measurement of blood pressure according to the European Society of Hypertension International Protocolo revision 2010:  the Omron HEM-7130, HEM-7320F and HEM-7500F.  Blood Pressure Monitoring 2015, 20:92-97
Omron HealthcareRS2 (HEM-6121-E) (Derivative of Omron RS3 (HEM-6130-E))WristInternational Protocol 2010IndependentTakahashi H, Yoshika M, and Yokoi T.  Validation of Omron RS8, RS6 and RS3 Home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocl revision 2010.  Blood Pressure Monitoring 2013, 9:265-272
Omron HealthcareRS6 (HEM-6221-E)WristInternational Protocol 2010IndependentPositioning sensor.  2 x LR03 batteries.  90 reading memoryTakahashi H, Yoshika M, Yokoi T.  Validation of Omron RS8, RS6 and RS3 home blood pressure monitoring devices, in accordance with the European Society of Hypertension International Protocol 2010.  Vascular Health and Risk Management 2013:9 265-272
Oregon ScientificBPW810Upper ArmInternational ProtocolIndependent2 x AAA Alkaline BatteriesLi Li, Wang Hui & Wu Jin Lan. Validation of the Oregon Scientific BPW810 blood pressure monitor according to the European Society of Hypertension Protocol. Blood Pressure Monitoring 2006, 11: 343-347
Oregon ScientificBPU 330Upper ArmInternational ProtocolIndependentLi L, Zhang X, Yan C & Liang Q. Validation of the Oregon Scientific BPU 330 for self-monitoring of blood pressure according to the International Protocol. Vascular Health and Risk Management 2008, 4(5):1121–1125
Oregon ScientificBPU321 (Derivative of Oregon Scientific BPU330)Upper ArmInternational ProtocolIndependent200 readings. 4 x AA batteriesLi L, Zhang XY, Yan CH, Liang QX.  Validation of the Oregorn Scientific BPU330 for self-monitoring of blood pressure according to the International Protocol.  Vascular Health & Risk Management. 2008, 4(5):1121-1125
Oregon ScientificTunstall BPU329Upper ArmInternational ProtocolIndependent200 readings.  Wireless transmissionLi L, Zhang XY, Yan CH, Liang QX.  Validation of the Oregorn Scientific BPU330 for self-monitoring of blood pressure according to the International Protocol.  Vascular Health & Risk Management. 2008, 4(5):1121-1125
PanasonicEW 3106Upper ArmInternational Protocol Independent42 reading memoryColeman A, Freeman P, Steel S & Shennan A. Validation of the Omron 705-IT (HEM-759-E) oscillometric blood pressure monitoring device according to the British Hypertension Society Protocol. Blood Pressure Monitoring 2006, 11(1):27-32
PanasonicEW 3109Upper ArmInternational Protocol Independent90 reading memoryBonso E, Dorigatti F & Palatini P. Validation of Panasonic EW3106 and EW 3109 devices for blood pressure measurement according to the International Protocol. Blood Pressure Monitoring 2010, 15(1):55-58
PangaoPG-800A11WristBHS A/AIndependent2 x 1.5V AAA batteriesAlso tested against International Protocol 2010 but insufficient data was reported to inform recommendationXie P, Wang Y, Xu X, Huang F and Pan J.  Validation of the Pangao PG-800A11 wrist device assessed according to the European Society of Hypertension and the British Hypertension Society protocols. Blood Pressure Monitoring 2015, 20:108-111
PangaoPG-800A36WristBHS A/AIndependent90 reading memory. Rechargeable batteryZhao H, Qiao W, Zhang R, Cui P, Hou F & Zhang W. Validation of the Pangao PG-800A36 automatic wrist blood
pressure monitor according to the European Society of Hypertension and the British Hypertension Society
protocols. Blood Pressure Monitoring 2018, 23:37-40
PangaoPG-800B11Upper ArmInternational Protocol 2010Independent90 reading memory, 4 x AA batteriesValidation approved according to the International Protocol 2010 onlyBing S, Zhang C, Wang L, Li L and Wan Y.  Validation of the Pangao PG-800B11 blood pressure monitor according to the European Society of Hypertension and the British Hypertension Society protocols.  Blood Pressure Monitoring 2014, 19:366-369
PangaoPG-800B5Upper ArmInternational Protocol 2010Independent90 reading memory, 4 x AA batteriesChen W, Zeng Z, Li L, Wan X, Wan Y.  Validation of the Pangao PG-800B5 for clinical use and self-measurement according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2014, 19:302-305
PangaoPG-800B26Upper ArmInternational Protocol 2010Independent2 x 90 reading memory. 4 x AA batteriesChen L, Li J, Wen J, Guo C, Zhang J & Yu Z. Validation of the Pangao PG-800B26 upper arm blood pressure monitor in
the general population according to the European Society of Hypertension and the British Hypertension Society
protocols. Blood Pressure Monitoring 2018, 23:41-44
PangaoPG-800B68Upper ArmInternational Protocol 2010Independent90 reading memory, 4 x AA batteries, voice functionYao R, Du YY, Li YP, Zhang YZ, Chen QH, Zhao LS and Li L.  Validation of the fully automated Pangao PG-800B68 upper arm device according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2015, 20:221-224
PhilipsDL8760Upper ArmInternational Protocol 2010IndependentChahinea MN,Bou Harb S, Saada AR, Sarkisa P, Azaki A, Aya Harba A, Alloucha A and Asmara R. Validation of the
PHILIPS DL8760 upper arm blood pressure
monitor, in oscillometry mode, for self-measurement in a
general population, according to the European Society of
Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2021, 26:237–241
Proton Healthcare888EA (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependent48 reading memory. 4 x AA batteriesde Greef A & Shennan AH. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society Protocol. Blood Pressure Monitoring 2007, 12:107-111
Proton Healthcare888UP (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependent99 reading memoryde Greef A & Shennan AH. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society Protocol. Blood Pressure Monitoring 2007, 12:107-111
Proton Healthcare868BF (Derivative of Health & Life HL868BA)Upper ArmInternational ProtocolIndependent180 reading memoryChen HE, Cui Y, Sheng CS, Li LH, Li Y & Wang JG. Validation of the Health & Life HL 868BA blood pressure monitor for home blood pressue monitoring according to the European Society of Hypertension Internationa protocol. Blood Pressure Monitoring 2008, 1
Qardio IncQardioArmUpper ArmInternational Protocol IndependentBluetooth requiring Quardio App. 4 x AAA BatteriesChahine MN, Topouchian J, Zelveian P, Hakobyan Z, Melkonyan A, Azaki A, Diab R, Harb A & Asmar R. Validation
of BP devices QardioArm in the general population and Omron M6 Comfort in type II diabetic patients acording
to the European Society of Hypertension International Protocol (ESH-IP). Dovepress Dec 2017, Vol 2018:11, 11-
20
RiesterRi-Champion N (OEM derivative of Microlife 3BTO-A)Upper ArmBHS A/AIndependent99 reading memory. 4 x AA batteries mains adaptor availableCuckson AC, Reinders A, Shabeeh H & Shennan AH. Validation of the Microlife 3BTO-A oscillometric blood pressure monitoring device according to a modified British Hypertension Society protocol. Blood Pressure Monitoring 2002, 7(6):319-324
Rossmax/AccumedAC1000f (Derivative of CF175)Upper ArmInternational Protocol 2010IndependentNB  Additional features on this device have not been tested for accuracy.  It is validated for its BP measurement function onlyZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AccumedC5 (Derivative of CF175)Upper ArmInternational Protocol 2010IndependentNB  Additional features on this device have not been tested for accuracy.  It is validated for its BP measurement function onlyZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AccumedCF155 (Derivative of CF175)Upper ArmInternational Protocol 2010IndependentZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AccumedCF175Upper ArmInternational Protocol 2010Independent90 reading memoryZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AccumedCH155 (Derivative of CF175)Upper ArmInternational Protocol 2010IndependentZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AccumedME/AB/AC/AD/AE/AF/AJ/MJ/MW-701, MA/MR/MV-801, AK/AT/AW/MG/MH/MJ-150, AD761, AU941, AV151, AV351,AC761f, AW151, MA350, MA351, MC100, MR250, MH901, MW821 (All models derivative of ME701)Upper ArmBHS A/A, International ProtocolIndependentde Greef A & Shennan AH. The Rossmax (ME701 Series) upper arm device: accuracy assessment in a adult population according to the International and the British Hypertension society protocols. Blood pressure Monitoring 2008, 13:43-48
Rossmax/AccumedX1, X3, X5 (Derivative of CF175)Upper ArmInternational Protocol 2010IndependentZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AccumedX9 (Derivative of CF175Upper ArmInternational Protocol 2010IndependentNB  Additional features on this device have not been tested for accuracy.  It is validated for its BP measurement function onlyZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AccumedZ1 (Derivative of CF175)Upper ArmInternational Protocol 2010IndependentZhang L, Kang YY, Zeng WF, Li Y and Wang JG. Validation of the Rossmax CF175 upper-arm blood pressure monitor
for home blood pressure monitoring according to the European Society of Hypertension International Protocol
revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AccumedZ5 (Derivative of CF175) Upper ArmInternational Protocol 2010IndependentZhang L, Kang YY, Zeng WF, Li Y and Wang JG. Validation of the Rossmax CF175 upper-arm blood pressure monitor
for home blood pressure monitoring according to the European Society of Hypertension International Protocol
revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AlvitaCG155f (Derivative of CF175)Upper ArmInternational Protocol 2010IndependentZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Rossmax/AlvitaMA801f (Derivative of CF175)Upper ArmInternational Protocol 2010IndependentZhang L, Kang YY, Zeng WF, Li Y and Wang JG.  Validation of the Rossmax CF175 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2015, 2: 104-107
Sabre Nederland BVBPM610(x) (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependentMinor protocol violation; only 2 observers used in the validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Sabre Nederland BVBPM701 (Derivative of Health & Life HL888HA)Upper ArmBHS A/AIndependentMinor protocol violation; only 2 observers used in the validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult population according to the British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
SCIANLD-735WristInternational Protocol 2010Independent2 x AAA batteries.  90 Reading memoryKang YY, Chen Q, Li Y and Wang JG.  Validation of the SCIAN LD-735 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2016, 21:255-258
Seagull apsS-868BA (OEM derivative of health & Life HL 868BAUpper ArmInternational Protocol IndependentChen HE, Cui Y, Sheng CS, Li LH, Li Y & Wang JG. Validation of the Health & Life HL 868BA blood pressure monitor for home blood pressue monitoring according to the European Society of Hypertension Internationa protocol. Blood Pressure Monitoring 2008, 113:305-308
Seagull apsS-888HA (OEM derivative of Health & Life HL 888HA)Upper ArmInternational ProtocolIndependentMinor protocol violation; only 2 observers used in the validation studyde Greef A, & Shennan A. The Health & Life device (HL888HA): accuracy assessment in an adult populatio according to th British Hypertension Society protocol. Blood Pressure Monitoring 2007, 12:107-111
Seinex (Forecare)SE-9400Upper ArmInternational ProtocolIndependent140 reading memory. 4 x AA batteriesTopouchian JA, El Assaad MA, Orobinskaia LV, El Feghali RN & Asmar RG. Validation of two automatic devices for self-measurement of brachial blood pressure according to the International Protocol of the European Society of Hypertension: the Seinex SE-9400 and the Microlife BP 3AC1-1. Blood Pressure Monitoring 2005, 10(6):325-331
SEJOYBP-1307Upper ArmInternational Protocol 2010Independent4 x AA Batteries or mains adapter. 2 x 60 reading memoryLei L, Chen Y, Chen Q, Li Y & Wang JG. Validation of the SEJOY BP-1307 upper-arm blood pressure monitor for
home blood pressure monitoring according to the European Society of Hypertension International Protocol
Revision 2010. Blood Pressure Monitoring 2017, 22:371-374
SensacareSAA-102Upper ArmBHS A/A, International ProtocolIndependentZaetta V, Daniele L, Pertkovic D, Prattico F, Barisa M, Perfetti P, Gabrieli A, Buonocore F & Winnick M. Validation of the SAA-102 home blood pressure monitor according to the protocols of the European Society of Hypertension, the Association for athe Advancement of Medical Instrumentation and the British Society of Hypertension. Blood Pressure Monitoring 2007, 12:363-368
SensacareSAW-102WristBHS B/B, International ProtocolIndependentZaetta V, Longo D, Perkovic D, Perfetti P, Gabrieli A, Prattico F & Winnicki M. Validation of the SAW-102 wrist home blood pressure monitor according to the protocols of the British Hypertension Society, the Association for teh Advancement of Medical Instrumentation and the European Society of Hypertension. Blood Pressure Monitoring 2009, 14:32-36
SpenglerTB-101, SMS-Pro (Derivative of KP-7500D)Upper ArmInternational ProtocolIndependentBelghazi J, El Feghali RN, Moussalem T, Rejdych M & Asmar R. Validation of four automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension. Vascular Health & Risk Management 2007:3(4) 1-12
Suntech247Vital SignsBHS A/A, International ProtocolIndependentFriz HP, Facchetti R, Primitz L, Beltrame L, Galbiati V, Ricioppo A, Bombelli M & Sega R. Simultaneous validation of the SunTech 247 diagnostic station blood pressure measurement device according to the British Hypertension Society protocol, the International Protocol and the Association for the Advancement of Medical Instrumentation standards. Blood Pressure Monitoring 2009, 14:222-227
SuntechCT40 Upper ArmBHS A/A, International ProtocolIndependent99 reading memoryFriz HP, Punzi V, Petri F, Orlandi R, Maggionini D, Priz MP, Primitz L & Vighi G. Similtaneous validation of the
SunTech CT40 automated blood pressure measurement device by th 1993 British Hypertension Society
protocol and the Association for the Advancement of Medical Instrumentaion/International Organization for
Standardization 81060-2:2013 standard. Blood Pressure Monitoring 2017, 22:298-301
ThermorBIOS BD215Upper ArmInternational Protocol 2010IndependentBenetti E, Fania C, Marquez Hernandez V, Palatini P.  Validation of the Thermor BIOS BD215 device for home blood pressure measurement according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2014, 19:176-179
TranstekTMB-986Upper ArmInternational Protocol Independent2 x 60 readings. 4 x AAA batteriesLiu WJ, Li SG, Song Z & Gong W. Validation of the Transtek blood pressure monitor TMB-986 for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2010, 15:287-280
TranstekTMB-988WristInternational Protocol Independent2 x AAA Alkaline BatteriesTian HY, Liu WJ, Li SG, Song Z & Gong W. Validation of the Transtek TMB-988 wrist blood pressure monitor for home blood pressure monitoring according to the International Protocol. Blood Pressure Monitoring 2010, 15:326-328
TranstekTMB-1491Upper ArmInternational Protocol 2010Independent60 reading memory x 2, four AAA batteriesTian H, Zeng S, Zhong X, Gong W and Liu W.  Validation of Transtek blood pressure monitor TMB-1491 for self-measurement according to the European Society of Hypertension International Protocol revision 2010.  Blood Pressure Monitoring 2015, 20:280-282
TranstekTMB-1776 Upper ArmInternational Protocol 2010IndependentLiu Z and Chen L. Validation of Transtek TMB-1776 according to European Society of Hypertension International
Protocol revision 2010 in adults. Blood Pressure Monitoring 2019, 24:319–322
UEBEVisomat Double ComfortUpper ArmInternational Protocol IndependentValidated in both auscultatory and oscillometric mode.Masiero S, Fania C & Palatini P. Validation of the UEBE Visomat Double Comfort upper arm blood pressure monitor in auscultation mode for clinic use and self-measurement in a general population according to the European Society of Hypertension International Protocol revision 2010. Blood Pressure Monitoring 2011, 16:208-210. Masiero S, Fania C & Palatini P. Validation of the UEBE Visomat Double Comfort upper arm blood pressure monitor, in oscillometric mode, for clinic use and self-measurement in a general population according to the European Society of Hypertension International Protocol revision 2012. Blood Pressure Monitoring 2011, 16:262-264
UEBEVisomat Handy WristWristInternational ProtocolIndependentSaladini F, Benetti E & Palatini P. Accuracy of the visomat handy wrist blood pressure measuring device according to the International Protocol. Blood Pressure Monitoring 2010, 15:281-284
UEBEVisomat ComfortUpper ArmInternational ProtocolIndependentBonso E, Dorigatti F, Saladini F & Palatini P. Validation of the Visomat Comfort from device for home blood pressure measurement according to the International Protocol. Blood Pressure Monitoring 201, 15(1):63-66
UEBEVisomat Comfort EcoUpper ArmInternational ProtocolIndependentPerkovic D, Guarnieri C & Palatini P. Validation of the Visomat Comfort Eco blood pressure measuring device according to the International Protocol. Blood Pressure Monitoring 2009, 14:178-180
VisocorHM40WristInternational ProtocolIndependentDorigatti F, Bonso E, Saldini F & Palatini P. Validation of the Visocor HM 40 wrist blood pressure measuring device according to the International Protocol. Blood Pressure Monitoring 2009, 14:32-36
WithingsBPM Connect PRO
(WPM06)(Derivative of
BPM Connect WPM05)
Upper ArmInternational ProtocolIndependentJirar Topouchian, Parounak Zelveian, Zoya Hakobyan, Heghine Gharibyan, Roland Asmar
Accuracy of the Withings BPM Connect Device for Self-Blood Pressure Measurements in General Population –
Validation According to the Association for the Advancement of Medical Instrumentation/European Society of
Hypertension/International
Organization for Standardization Universal Standard
Vascular Health and Risk Management 2022:18 191–200
Zelveian P, Topouchian J, Hakobyan Z, Asmar J, Gharibyan H, Asmar R
Clinical Accuracy of the Withings BPM Connect for Self-Blood Pressure Measurements in Pregnancy and PreEclampsia: Validation According to the Association for the Advancement of Medical Instrumentation/European
Society of Hypertension/International
Organization for Standardization Universal Standard
Vascular Health and Risk Management, 2022, 18, 181–189
Withings BPM Connect (WPM05) Upper ArmInternational ProtocolIndependentJirar Topouchian, Parounak Zelveian, Zoya Hakobyan, Heghine Gharibyan, Roland Asmar
Accuracy of the Withings BPM Connect Device for Self-Blood Pressure Measurements in General Population –
Validation According to the Association for the Advancement of Medical Instrumentation/European Society of
Hypertension/International
Organization for Standardization Universal Standard
Vascular Health and Risk Management 2022:18 191–200
Zelveian P, Topouchian J, Hakobyan Z, Asmar J, Gharibyan H, Asmar R
Clinical Accuracy of the Withings BPM Connect for Self-Blood Pressure Measurements in Pregnancy and PreEclampsia: Validation According to the Association for the Advancement of Medical Instrumentation/European
Society of Hypertension/International
Organization for Standardization Universal Standard
Vascular Health and Risk Management, 2022, 18, 181–189
YuWellYE690AUpper ArmInternational ProtocolIndependent2 x 74 reading memory. Large cuff up to 45cmChen Q, Lei L, Li Y & Wang JG. Validation of the YuWell YE690A upper-arm blood pressure monitor for clinical
use and self-measurement according to the European Society of Hypertension International Protocol Revision
2010. Blood Pressure Monitoring 2017, 22:295-297